{"product_id":"okonite-161-23-6072-1-0-aluminum-35kv-underground-primary-distribution-cable-epr-full-neutral-100-345ml","title":"Okonite 161-23-6072, 1\/0 Aluminum 35kv Underground Primary Distribution Cable, EPR, Full Neutral 100%,  345ML","description":"\u003cdiv class=\"page\" title=\"Page 1\" style='color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif; font-size: 15px;'\u003e\u003cdiv class=\"layoutArea\"\u003e\u003cdiv class=\"column\"\u003e\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px;\"\u003e\u003cspan style=\"font-weight: 700;\"\u003e35kV Underground Primary Distribution Cable-Jacketed Red Identification Stripes\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAluminum Conductor\/105°C Rating\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003e100% and 133% Insulation Levels\u003c\/span\u003e\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003cbr\u003e\u003c\/span\u003eOkoguard URO-J cables provide maximum circuit longevity in underground residential distribution systems. They can be buried di- rectly or installed in underground ducts or conduits.\u003c\/p\u003e\u003cdiv class=\"page\" title=\"Page 1\" style='color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif; font-size: 15px;'\u003e\u003cdiv class=\"layoutArea\"\u003e\u003cdiv class=\"column\"\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px;\"\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications:\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eCentral Conductor:\u003c\/span\u003e Aluminum per ASTM B-609, Class B stranded per B-231.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px;\"\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Screen:\u003c\/span\u003e Extruded semiconduct- ing ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px;\"\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e Extruded Okoguard meets or ex- ceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px;\"\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Screen:\u003c\/span\u003e Extruded semiconduct- ing ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px;\"\u003e\u003cspan style=\"font-weight: 700;\"\u003eConcentric Conductor:\u003c\/span\u003e Bare copper wires.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px;\"\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e Black Okolene with red extruded stripes meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5 for polyethylene jackets.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003cbr\u003e\u003c\/span\u003eOkoguard is Okonite's registered trade name for its exclusive ethylene-propylene rubber (EPR) based, thermosetting compound, whose optimum balance of electrical and physical properties is unequaled in other solid dielectrics. Okoguard insulation, with the distinctive red color and a totally inte- grated EPR system, provides the optimum balance of electrical and physical properties for long, problem free service.\u003c\/p\u003e\u003cdiv class=\"page\" title=\"Page 1\" style='color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif; font-size: 15px;'\u003e\u003cdiv class=\"layoutArea\"\u003e\u003cdiv class=\"column\"\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px;\"\u003eThe triple tandem extrusion of the screens with the insulation provides optimum electri- cal characteristics.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px;\"\u003eAn insulation screen of ethylene-propylene rubber is extruded over the insulation. The bare copper concentric wires are uniformly spaced around the insulation screen. The overall polyethylene jacket provides protec- tion against mechanical damage and corrosion.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px;\"\u003eProduct identification is provided through the use of three red stripes placed 120° apart in the black jacket, with an NESC lightning bolt.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eVoltage: \u003c\/span\u003e \u003cbr\u003e35 kV\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 1\/0\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eOutside Diameter: \u003c\/span\u003e1.044 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eWeight:\u003c\/span\u003e 1.17 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAmpacity: \u003c\/span\u003eDuct =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 165 amps @ 90C\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793715126466,"sku":"OGCW4725","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/10686_1_85f05854-77eb-46cb-8cdc-fc90ca795fd9.png?v=1771606249","url":"https:\/\/ayepc2-wv.myshopify.com\/products\/okonite-161-23-6072-1-0-aluminum-35kv-underground-primary-distribution-cable-epr-full-neutral-100-345ml","provider":"Testing Developer Store","version":"1.0","type":"link"}