{"product_id":"1000-mcm-xhhw-building-wire","title":"1000 MCM XHHW Copper Building Wire","description":"\u003cp\u003e\u003cstrong\u003eCURRENTLY OUT OF STOCK!!!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMinimum 25' to maximum 175'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor:\u003c\/strong\u003e\u003cbr\u003eBlack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eType XHHW-2\/RW90 building wire is intended for general purpose applications utilized in conduit, underground in conduit, or other recognized raceways for services, feeders, and branch-circuit wiring as specified in the National Electrical Code (NEC). Type XHHW-2\/RW90 is permitted for 600 volt applications and can be used in wet or dry locations at temperatures not to exceed 90_C. Suitable for applications requiring low-leaking circuits and a dielectric constant of 3.5 or less.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003eAvailable in sizes 14 AWG through 1000 KCMIL. On 250 KCMIL and larger, sequential foot markings located every foot for easy measuring. For 1 AWG through 4\/0 AWG, sequential foot markings on master reels only unless otherwise specified. 6 AWG and larger rated Sunlight Resistant in all colors. 1\/0 AWG and larger are rated for cable tray use and comply with IEEE 1202\/FT4 (70,000 Btu\/hr) flame test and ICEA T-29-520 (210,000 Btu\/hr) flame test.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eUnderwriters Laboratories Standard UL-44\u003cbr\u003eASTM Stranding Class B3, B8, B787\u003cbr\u003eFederal Specification A-A-59544\u003cbr\u003eCanadian Standards Association C22.2 No. 38\u003cbr\u003eNEMA WC-70\/ICEA S-95-658\u003cbr\u003eNFPA 70: National Electrical Code (NEC)\u003cbr\u003eUL 1685-FT4\/IEEE 1202 (70,000 Btu\/hr) Flame Test (1\/0 AWG and larger)\u003cbr\u003eICEA T-29-520 (210,000 Btu\/hr) Flame Test\u003cbr\u003eARRA 2009; Section 1605 \"Buy American\" Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cbr\u003e\u003ci\u003eConductors:\u003c\/i\u003e\u003cbr\u003eStranded, uncoated bare copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8\u003cbr\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003cbr\u003eCross-linked polyethylene (XLPE) insulation per UL-44\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e1000 MCM\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e61\u003cbr\u003e\u003cb\u003eInsulation Thickness XLPE:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e2.03 mm \/ 0.080 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e33.32 mm \/ 1.312 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e3.270 lbs per ft\u003cbr\u003e\u003cb\u003eAllowable Ampacity:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e455 Amps at 60ºC \/ 545 Amps at 75ºC \/ 615 Amps at 90ºC\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793807073474,"sku":"1GCW2258","price":44.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/xhhw_copper_master_1_350fe640-5001-4be6-bafe-8dcde12abbbf.webp?v=1771606838","url":"https:\/\/ayepc2-wv.myshopify.com\/products\/1000-mcm-xhhw-building-wire","provider":"Testing Developer Store","version":"1.0","type":"link"}