{"title":"Medium Voltage Cable","description":"","products":[{"product_id":"prysmian-airguard-cable-350-mcm-3-conductor-type-mv-105-5kv-133-medium-voltage-cable","title":"Prysmian Airguard Cable, 350 MCM 3 Conductor Type MV-105, 5kV, 133%, Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003eThree conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication \u0026amp; Benefits:\u003c\/strong\u003e\u003cbr\u003ePrysmian’s patented AIRGUARD™ cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations or if installed with cables rated 1000V or greater) with 5X the impact performance and 2X-3X the sidewall bearing pressure limit (@ 3000 lbs per rad-ft) This enables longer pulls than with Continuously Corrugated and Welded type cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMetalic Shield:\u003c\/strong\u003e\u003cbr\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a minimum overlap of 15%. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification -1C w\/Red, 1C w\/Blue, and 1C w\/Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003cbr\u003eBare Stranded copper conductor, one in each interstice, per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003cbr\u003ePhase identified shielded conductors cabled with fillers and grounding conductors (as specified), forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003cbr\u003eHigh strength and high crush resistant Airbag Layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003cbr\u003eA layer of Drylam which consists of aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003eSunlight resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards: \u003c\/strong\u003e \u003cbr\u003eICEA S-93-639\/NEMA WC74 Type MV 105 UL 1072 For CT USE, Direct Buried, Sunlight Resistant, IEEE 383 Flame Test IEEE 1202 Flame Test ICEA T-29-520 at 210,000 BTU\/hr MSHA Type MP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 350\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 90 mils\u003cbr\u003e\u003cb\u003eNumber of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3 \u003cbr\u003e\u003cb\u003eSize of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e6 AWG\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.622 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.86 nches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.92 inches\u003cbr\u003e\u003cb\u003eOverall Jacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e2.52 inches\u003cbr\u003e\u003cb\u003eCable Weight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e5.899 lbs per ft\u003cbr\u003e\u003cb\u003eMinumum Bend Radius:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e18 inches\u003cbr\u003e\u003cb\u003eAmpacity:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e105C in Duct =\u003cb\u003e \u003c\/b\u003e 380 amps -  In air =\u003cb\u003e \u003c\/b\u003e 440 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793706541250,"sku":"PGCW4825","price":76.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/15549.webp?v=1771606124"},{"product_id":"prysmian-airguard-cable-250-mcm-3-conductor-type-mv-105-5kv-133-medium-voltage-cable","title":"Prysmian Airguard Cable, 250 MCM 3 Conductor Type MV-105, 5kV, 133%, Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003eThree conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication \u0026amp; Benefits:\u003c\/strong\u003e\u003cbr\u003ePrysmian’s patented AIRGUARD™ cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations or if installed with cables rated 1000V or greater) with 5X the impact performance and 2X-3X the sidewall bearing pressure limit (@ 3000 lbs per rad-ft) This enables longer pulls than with Continuously Corrugated and Welded type cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMetalic Shield:\u003c\/strong\u003e\u003cbr\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a minimum overlap of 15%. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification -1C w\/Red, 1C w\/Blue, and 1C w\/Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003cbr\u003eBare Stranded copper conductor, one in each interstice, per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003cbr\u003ePhase identified shielded conductors cabled with fillers and grounding conductors (as specified), forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003cbr\u003eHigh strength and high crush resistant Airbag Layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003cbr\u003eA layer of Drylam which consists of aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003eSunlight resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards: \u003c\/strong\u003e \u003cbr\u003eICEA S-93-639\/NEMA WC74 Type MV 105 UL 1072 For CT USE, Direct Buried, Sunlight Resistant, IEEE 383 Flame Test IEEE 1202 Flame Test ICEA T-29-520 at 210,000 BTU\/hr MSHA Type MP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 250\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 90 mils\u003cbr\u003e\u003cb\u003eNumber of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3 \u003cbr\u003e\u003cb\u003eSize of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e6 AWG\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.522 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.76 nches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.82 inches\u003cbr\u003e\u003cb\u003eOverall Jacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e2.31 inches\u003cbr\u003e\u003cb\u003eCable Weight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e4.562 lbs per ft\u003cbr\u003e\u003cb\u003eMinumum Bend Radius:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e17 inches\u003cbr\u003e\u003cb\u003eAmpacity:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e105C in Duct =\u003cb\u003e \u003c\/b\u003e 315 amps -  In air =\u003cb\u003e \u003c\/b\u003e 355 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793706574018,"sku":"PGCW4824","price":71.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/15549_ebc8f976-e335-4505-a697-d0757f661e6c.webp?v=1771606125"},{"product_id":"prysmian-airguard-cable-4-0-awg-3-conductor-type-mv-105-5kv-133-medium-voltage-cable","title":"Prysmian Airguard Cable, 4\/0 AWG 3 Conductor Type MV-105, 5kV, 133%, Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003eThree conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication \u0026amp; Benefits:\u003c\/strong\u003e\u003cbr\u003ePrysmian’s patented AIRGUARD™ cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations or if installed with cables rated 1000V or greater) with 5X the impact performance and 2X-3X the sidewall bearing pressure limit (@ 3000 lbs per rad-ft) This enables longer pulls than with Continuously Corrugated and Welded type cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMetalic Shield:\u003c\/strong\u003e\u003cbr\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a minimum overlap of 15%. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification -1C w\/Red, 1C w\/Blue, and 1C w\/Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003cbr\u003eBare Stranded copper conductor, one in each interstice, per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003cbr\u003ePhase identified shielded conductors cabled with fillers and grounding conductors (as specified), forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003cbr\u003eHigh strength and high crush resistant Airbag Layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003cbr\u003eA layer of Drylam which consists of aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003eSunlight resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards: \u003c\/strong\u003e \u003cbr\u003eICEA S-93-639\/NEMA WC74 Type MV 105 UL 1072 For CT USE, Direct Buried, Sunlight Resistant, IEEE 383 Flame Test IEEE 1202 Flame Test ICEA T-29-520 at 210,000 BTU\/hr MSHA Type MP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 4\/0\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 90 mils\u003cbr\u003e\u003cb\u003eNumber of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3 \u003cbr\u003e\u003cb\u003eSize of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7 AWG\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.479 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.71 inches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.76 inches\u003cbr\u003e\u003cb\u003eOverall Jacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e2.22 inches\u003cbr\u003e\u003cb\u003eCable Weight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e4.068 lbs per ft\u003cbr\u003e\u003cb\u003eMinumum Bend Radius:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e16 inches\u003cbr\u003e\u003cb\u003eAmpacity:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e105C in Duct =\u003cb\u003e \u003c\/b\u003e 285 amps -  In air =\u003cb\u003e \u003c\/b\u003e 320 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793706639554,"sku":"PGCW4823","price":57.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/15549_30583b2f-9cdd-4f3d-818e-2f0309eaf8df.webp?v=1771606126"},{"product_id":"prysmian-airguard-cable-2-0-awg-3-conductor-type-mv-105-5kv-133-medium-voltage-cable","title":"Prysmian Airguard Cable, 2\/0 AWG 3 Conductor Type MV-105, 5kV, 133%, Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003eThree conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication \u0026amp; Benefits:\u003c\/strong\u003e\u003cbr\u003ePrysmian’s patented AIRGUARD™ cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations or if installed with cables rated 1000V or greater) with 5X the impact performance and 2X-3X the sidewall bearing pressure limit (@ 3000 lbs per rad-ft) This enables longer pulls than with Continuously Corrugated and Welded type cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMetalic Shield:\u003c\/strong\u003e\u003cbr\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a minimum overlap of 15%. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification -1C w\/Red, 1C w\/Blue, and 1C w\/Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003cbr\u003eBare Stranded copper conductor, one in each interstice, per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003cbr\u003ePhase identified shielded conductors cabled with fillers and grounding conductors (as specified), forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003cbr\u003eHigh strength and high crush resistant Airbag Layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003cbr\u003eA layer of Drylam which consists of aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003eSunlight resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards: \u003c\/strong\u003e \u003cbr\u003eICEA S-93-639\/NEMA WC74 Type MV 105 UL 1072 For CT USE, Direct Buried, Sunlight Resistant, IEEE 383 Flame Test IEEE 1202 Flame Test ICEA T-29-520 at 210,000 BTU\/hr MSHA Type MP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 2\/0\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 90 mils\u003cbr\u003e\u003cb\u003eNumber of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3 \u003cbr\u003e\u003cb\u003eSize of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e8 AWG\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.376 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.600 inches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.66 inches\u003cbr\u003e\u003cb\u003eOverall Jacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.97 inches\u003cbr\u003e\u003cb\u003eCable Weight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e2.942 lbs per ft\u003cbr\u003e\u003cb\u003eMinumum Bend Radius:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e17 inches\u003cbr\u003e\u003cb\u003eAmpacity:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e105C in Duct =\u003cb\u003e \u003c\/b\u003e 220 amps -  In air =\u003cb\u003e \u003c\/b\u003e 240 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793706705090,"sku":"PGCW4822","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/15549_d432c374-02f8-4f73-bf9b-3ecd583213f4.webp?v=1771606127"},{"product_id":"prysmian-airguard-cable-1-0-awg-3-conductor-type-mv-105-5kv-133-medium-voltage-cable","title":"Prysmian Airguard Cable, 1\/0 AWG 3 Conductor Type MV-105, 5kV, 133%, Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003eThree conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication \u0026amp; Benefits:\u003c\/strong\u003e\u003cbr\u003ePrysmian’s patented AIRGUARD™ cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations or if installed with cables rated 1000V or greater) with 5X the impact performance and 2X-3X the sidewall bearing pressure limit (@ 3000 lbs per rad-ft) This enables longer pulls than with Continuously Corrugated and Welded type cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMetalic Shield:\u003c\/strong\u003e\u003cbr\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a minimum overlap of 15%. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification -1C w\/Red, 1C w\/Blue, and 1C w\/Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003cbr\u003eBare Stranded copper conductor, one in each interstice, per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003cbr\u003ePhase identified shielded conductors cabled with fillers and grounding conductors (as specified), forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003cbr\u003eHigh strength and high crush resistant Airbag Layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003cbr\u003eA layer of Drylam which consists of aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003eSunlight resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards: \u003c\/strong\u003e \u003cbr\u003eICEA S-93-639\/NEMA WC74 Type MV 105 UL 1072 For CT USE, Direct Buried, Sunlight Resistant, IEEE 383 Flame Test IEEE 1202 Flame Test ICEA T-29-520 at 210,000 BTU\/hr MSHA Type MP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 1\/0\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 90 mils\u003cbr\u003e\u003cb\u003eNumber of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3 \u003cbr\u003e\u003cb\u003eSize of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e8 AWG\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.341 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.570 inches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.620 inches\u003cbr\u003e\u003cb\u003eOverall Jacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.89 inches\u003cbr\u003e\u003cb\u003eCable Weight:\u003c\/b\u003e 2.565 lbs per ft\u003cbr\u003e\u003cb\u003eMinumum Bend Radius:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e14 inches\u003cbr\u003e\u003cb\u003eAmpacity:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e105C in Duct =\u003cb\u003e \u003c\/b\u003e 190 amps -  In air =\u003cb\u003e \u003c\/b\u003e 205 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793706770626,"sku":"PGCW4821","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/15549_a13090be-5c9b-4044-a1c5-baa2422c96f1.webp?v=1771606128"},{"product_id":"prysmian-airguard-cable-1-awg-3-conductor-type-mv-105-5kv-133-medium-voltage-cable","title":"Prysmian Airguard Cable, 1 AWG 3 Conductor Type MV-105, 5kV, 133%, Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003eThree conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication \u0026amp; Benefits:\u003c\/strong\u003e\u003cbr\u003ePrysmian’s patented AIRGUARD™ cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations or if installed with cables rated 1000V or greater) with 5X the impact performance and 2X-3X the sidewall bearing pressure limit (@ 3000 lbs per rad-ft) This enables longer pulls than with Continuously Corrugated and Welded type cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPROTENAXTM EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMetalic Shield:\u003c\/strong\u003e\u003cbr\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003cbr\u003eBare stranded copper conductor per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003cbr\u003ePhase identified shielded conductors cabled with fillers and grounding conductors (as specified), forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003cbr\u003eHigh strength and high crush resistant Airbag Layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003cbr\u003eA layer of Drylam which consists of aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003eSunlight resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards: \u003c\/strong\u003e \u003cbr\u003eICEA S-93-639\/NEMA WC74 Type MV 105 UL 1072 For CT USE, Direct Buried, Sunlight Resistant, IEEE 383 Flame Test IEEE 1202 Flame Test ICEA T-29-520 at 210,000 BTU\/hr MSHA Type MP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 1 AWG\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 90 mils\u003cbr\u003e\u003cb\u003eNumber of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3 \u003cbr\u003e\u003cb\u003eSize of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e8 AWG\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.299 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.530 inches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.58 inches\u003cbr\u003e\u003cb\u003eOverall Jacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.71 inches\u003cbr\u003e\u003cb\u003eCable Weight: \u003c\/b\u003e2.107 lbs per ft\u003cbr\u003e\u003cb\u003eMinumum Bend Radius:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e12 inches\u003cbr\u003e\u003cb\u003eAmpacity:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e105C in Duct =\u003cb\u003e \u003c\/b\u003e 165 amps -  In air =\u003cb\u003e \u003c\/b\u003e 180 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793706836162,"sku":"PGCW4820","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/15549_1464f742-d5a0-435b-a205-3cd5e7ff1529.webp?v=1771606129"},{"product_id":"prysmian-airguard-cable-2-awg-3-conductor-type-mv-105-5kv-133-medium-voltage-cable","title":"Prysmian Airguard Cable, 2 AWG 3 Conductor Type MV-105, 5kV, 133%, Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003eThree conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication \u0026amp; Benefits:\u003c\/strong\u003e\u003cbr\u003ePrysmian’s patented AIRGUARD™ cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations or if installed with cables rated 1000V or greater) with 5X the impact performance and 2X-3X the sidewall bearing pressure limit (@ 3000 lbs per rad-ft) This enables longer pulls than with Continuously Corrugated and Welded type cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMetalic Shield:\u003c\/strong\u003e\u003cbr\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a minimum overlap of 15%. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification -1C w\/Red, 1C w\/Blue, and 1C w\/Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003cbr\u003eBare Stranded copper conductor, one in each interstice, per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003cbr\u003ePhase identified shielded conductors cabled with fillers and grounding conductors (as specified), forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003cbr\u003eHigh strength and high crush resistant Airbag Layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003cbr\u003eA layer of Drylam which consists of aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003eSunlight resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards: \u003c\/strong\u003e \u003cbr\u003eICEA S-93-639\/NEMA WC74 Type MV 105 UL 1072 For CT USE, Direct Buried, Sunlight Resistant, IEEE 383 Flame Test IEEE 1202 Flame Test ICEA T-29-520 at 210,000 BTU\/hr MSHA Type MP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 2 AWG\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 90 mils\u003cbr\u003e\u003cb\u003eNumber of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3 \u003cbr\u003e\u003cb\u003eSize of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e10 AWG\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.266 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.490 inches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.550 inches\u003cbr\u003e\u003cb\u003eOverall Jacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.640 inches\u003cbr\u003e\u003cb\u003eCable Weight:\u003c\/b\u003e 1.855 lbs per ft\u003cbr\u003e\u003cb\u003eMinumum Bend Radius:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e12 inches\u003cbr\u003e\u003cb\u003eAmpacity:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e105C in Duct =\u003cb\u003e \u003c\/b\u003e 145 amps -  In air =\u003cb\u003e \u003c\/b\u003e 154 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793706901698,"sku":"PGCW4819","price":28.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/15549_f7916fe6-e9a8-4ad4-9334-cd3a97013ba0.webp?v=1771606130"},{"product_id":"750-mcm-mv-105-25kv-35kv-epr-pvc-power-cable-w-copper-tape-shield-133-100-insulation","title":"750 MCM MV-105, 25kV\/35kV, EPR\/PVC Power Cable w\/ Copper Tape Shield, 133%\/100% Insulation","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 25\/35 kV when installed in open air, conduit, duct, or direct buried, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClass B stranded, annealed, bare copper per ASTM B-3, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semiconducting, thermosetting compound\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEthylene Propylene Rubber (EPR), physical and electrical properties are in accordance with ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBased on three single conductor cables in isolated conduit in air per 2008 NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e25\/35kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 750 MCM\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.345 inches\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003c\/b\u003e 0.917 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.670 inches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.720 inches\u003cbr\u003e\u003cb\u003eJacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.950 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e3.67 lbs per ft\u003cbr\u003e\u003cb\u003eAmps In Duct:\u003c\/b\u003e 610 amps\u003cbr\u003e\u003cb\u003eAmps In Air:\u003c\/b\u003e 970 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793706934466,"sku":"7GCW4818","price":45.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/26345.webp?v=1771606131"},{"product_id":"500-mcm-mv-105-25kv-35kv-epr-pvc-power-cable-w-copper-tape-shield-133-100-insulation","title":"500 MCM MV-105, 25kV\/35kV, EPR\/PVC Power Cable w\/ Copper Tape Shield, 133%\/100% Insulation","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 25\/35 kV when installed in open air, conduit, duct, or direct buried, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClass B stranded, annealed, bare copper per ASTM B-3, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semiconducting, thermosetting compound\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEthylene Propylene Rubber (EPR), physical and electrical properties are in accordance with ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBased on three single conductor cables in isolated conduit in air per 2008 NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e25\/35kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 500 MCM\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.345 inches\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003c\/b\u003e 0.742 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.480 inches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.540 inches\u003cbr\u003e\u003cb\u003eJacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.700 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e2.54 lbs per ft\u003cbr\u003e\u003cb\u003eAmps In Duct:\u003c\/b\u003e 500 amps\u003cbr\u003e\u003cb\u003eAmps In Air:\u003c\/b\u003e 755 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793706967234,"sku":"5GCW4817","price":29.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/26345_b0b1775e-0695-4044-81e9-9543a571b3f1.webp?v=1771606132"},{"product_id":"350-mcm-mv-105-25kv-35kv-epr-pvc-power-cable-w-copper-tape-shield-133-100-insulation","title":"350 MCM MV-105, 25kV\/35kV, EPR\/PVC Power Cable w\/ Copper Tape Shield, 133%\/100% Insulation","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 25\/35 kV when installed in open air, conduit, duct, or direct buried, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClass B stranded, annealed, bare copper per ASTM B-3, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semiconducting, thermosetting compound\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEthylene Propylene Rubber (EPR), physical and electrical properties are in accordance with ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBased on three single conductor cables in isolated conduit in air per 2008 NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e25\/35kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 350 MCM\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.345 inches\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003c\/b\u003e 0.622 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.360 inches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.420 inches\u003cbr\u003e\u003cb\u003eJacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.580 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e1.99 lbs per ft\u003cbr\u003e\u003cb\u003eAmps In Duct:\u003c\/b\u003e 415 amps\u003cbr\u003e\u003cb\u003eAmps In Air:\u003c\/b\u003e 605 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793707000002,"sku":"3GCW4816","price":17.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/26345_41f47120-b718-4901-9e8a-29722273ea2e.webp?v=1771606133"},{"product_id":"250-mcm-mv-105-25kv-35kv-epr-pvc-power-cable-w-copper-tape-shield-133-100-insulation","title":"250 MCM MV-105, 25kV\/35kV, EPR\/PVC Power Cable w\/ Copper Tape Shield, 133%\/100% Insulation","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 25\/35 kV when installed in open air, conduit, duct, or direct buried, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClass B stranded, annealed, bare copper per ASTM B-3, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semiconducting, thermosetting compound\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEthylene Propylene Rubber (EPR), physical and electrical properties are in accordance with ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBased on three single conductor cables in isolated conduit in air per 2008 NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e25\/35kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 250 MCM\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.345 inches\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003c\/b\u003e 0.522 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.260 inches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.320 inches\u003cbr\u003e\u003cb\u003eJacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.480 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e1.65 lbs per ft\u003cbr\u003e\u003cb\u003eAmps In Duct:\u003c\/b\u003e 345 amps\u003cbr\u003e\u003cb\u003eAmps In Air:\u003c\/b\u003e 490 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793707032770,"sku":"2GCW4815","price":14.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/26345_65bdaafe-4f62-42a3-a13c-7fda7cf19784.webp?v=1771606134"},{"product_id":"4-0-mv-105-25kv-35kv-epr-pvc-power-cable-w-copper-tape-shield-133-100-insulation","title":"4\/0 MV-105, 25kV\/35kV, EPR\/PVC Power Cable w\/ Copper Tape Shield, 133%\/100% Insulation","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 25\/35 kV when installed in open air, conduit, duct, or direct buried, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClass B stranded, annealed, bare copper per ASTM B-3, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semiconducting, thermosetting compound\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEthylene Propylene Rubber (EPR), physical and electrical properties are in accordance with ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBased on three single conductor cables in isolated conduit in air per 2008 NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e25\/35kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 4\/0\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.345 inches\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003c\/b\u003e 0.479 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.210 inches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.270 inches\u003cbr\u003e\u003cb\u003eJacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.430 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e1.44 lbs per ft\u003cbr\u003e\u003cb\u003eAmps In Duct:\u003c\/b\u003e 315 amps\u003cbr\u003e\u003cb\u003eAmps In Air:\u003c\/b\u003e 445 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793707065538,"sku":"4GCW4814","price":11.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/26345_75b75f91-bc58-445c-bdae-fd3a17a584df.webp?v=1771606135"},{"product_id":"3-0-mv-105-25kv-35kv-epr-pvc-power-cable-w-copper-tape-shield-133-100-insulation","title":"3\/0 MV-105, 25kV\/35kV , EPR\/PVC Power Cable w\/ Copper Tape Shield, 133%\/100% Insulation","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 25\/35 kV when installed in open air, conduit, duct, or direct buried, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClass B stranded, annealed, bare copper per ASTM B-3, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semiconducting, thermosetting compound\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEthylene Propylene Rubber (EPR), physical and electrical properties are in accordance with ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBased on three single conductor cables in isolated conduit in air per 2008 NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e25\/35kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 3\/0\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.345 inches\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003c\/b\u003e 0.423 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.160 inches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.210 inches\u003cbr\u003e\u003cb\u003eJacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.380 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e1.31 lbs per ft\u003cbr\u003e\u003cb\u003eAmps In Duct:\u003c\/b\u003e 275 amps\u003cbr\u003e\u003cb\u003eAmps In Air:\u003c\/b\u003e 380 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793707131074,"sku":"3GCW4813","price":11.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/26345_4f4c4d1e-dc24-4743-9490-91d5b31955a4.webp?v=1771606136"},{"product_id":"2-0-mv-105-25kv-35kv-epr-pvc-power-cable-w-copper-tape-shield-133-100-insulation","title":"2\/0 MV-105, 25kV\/35kV, EPR\/PVC Power Cable w\/ Copper Tape Shield, 133%\/100% Insulation","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 25\/35 kV when installed in open air, conduit, duct, or direct buried, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClass B stranded, annealed, bare copper per ASTM B-3, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semiconducting, thermosetting compound\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEthylene Propylene Rubber (EPR), physical and electrical properties are in accordance with ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBased on three single conductor cables in isolated conduit in air per 2008 NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e25\/35kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 2\/0\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.345 inches\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003c\/b\u003e 0.376 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.110 inches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.170 inches\u003cbr\u003e\u003cb\u003eJacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.330 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e1.17 lbs per ft\u003cbr\u003e\u003cb\u003eAmps In Duct:\u003c\/b\u003e 245 amps\u003cbr\u003e\u003cb\u003eAmps In Air:\u003c\/b\u003e 330 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793707163842,"sku":"2GCW4812","price":11.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/26345_b6e59c5f-d916-462e-a5a5-7570c4f4b724.webp?v=1771606137"},{"product_id":"1-0-mv-105-25kv-35kv-epr-pvc-power-cable-w-copper-tape-shield-133-100-insulation","title":"1\/0 MV-105, 25kV\/35kV , EPR\/PVC Power Cable w\/ Copper Tape Shield, 133%\/100% Insulation","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 25\/35 kV when installed in open air, conduit, duct, or direct buried, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClass B stranded, annealed, bare copper per ASTM B-3, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semiconducting, thermosetting compound\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEthylene Propylene Rubber (EPR), physical and electrical properties are in accordance with ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBased on three single conductor cables in isolated conduit in air per 2008 NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e25\/35kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 1\/0\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.345 inches\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003c\/b\u003e 0.341 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.080 inches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.130 inches\u003cbr\u003e\u003cb\u003eJacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.290 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e1.01 lbs per ft\u003cbr\u003e\u003cb\u003eAmps In Duct:\u003c\/b\u003e 215 amps\u003cbr\u003e\u003cb\u003eAmps In Air:\u003c\/b\u003e 290 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793707196610,"sku":"1GCW4811","price":14.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/26345_432c25ae-cc99-4da4-9ff7-104f3b86f46f.webp?v=1771606138"},{"product_id":"prysmian-airguard-cable-1000-mcm-3-conductor-type-mv-105-15kv-133-medium-voltage-cable","title":"Prysmian Airguard Cable, 1000 MCM 3 Conductor Type MV-105, 15kV, 133%, Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003eThree conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication \u0026amp; Benefits:\u003c\/strong\u003e\u003cbr\u003ePrysmian’s patented AIRGUARD™ cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations or if installed with cables rated 1000V or greater) with 5X the impact performance and 2X-3X the sidewall bearing pressure limit (@ 3000 lbs per rad-ft) This enables longer pulls than with Continuously Corrugated and Welded type cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMetalic Shield:\u003c\/strong\u003e\u003cbr\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a minimum overlap of 15%. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification -1C w\/Red, 1C w\/Blue, and 1C w\/Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003cbr\u003eBare Stranded copper conductor, one in each interstice, per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003cbr\u003ePhase identified shielded conductors cabled with fillers and grounding conductors (as specified), forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003cbr\u003eHigh strength and high crush resistant Airbag Layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003cbr\u003eA layer of Drylam which consists of aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003eSunlight resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards: \u003c\/strong\u003e \u003cbr\u003eICEA S-93-639\/NEMA WC74 Type MV 105 UL 1072 For CT USE, Direct Buried, Sunlight Resistant, IEEE 383 Flame Test IEEE 1202 Flame Test ICEA T-29-520 at 210,000 BTU\/hr MSHA Type MP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 7000\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 220 mils\u003cbr\u003e\u003cb\u003eNumber of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3 \u003cbr\u003e\u003cb\u003eSize of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3 AWG\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.071 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.57 nches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.62 inches\u003cbr\u003e\u003cb\u003eOverall Jacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e4.17 inches\u003cbr\u003e\u003cb\u003eCable Weight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e16.233 lbs per ft\u003cbr\u003e\u003cb\u003eMinumum Bend Radius:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e30 inches\u003cbr\u003e\u003cb\u003eAmpacity:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e105C in Duct =\u003cb\u003e \u003c\/b\u003e 660 amps -  In air =\u003cb\u003e \u003c\/b\u003e 860 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793707229378,"sku":"PGCW4810","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/15426.webp?v=1771606139"},{"product_id":"prysmian-airguard-cable-750-mcm-3-conductor-type-mv-105-15kv-133-medium-voltage-cable","title":"Prysmian Airguard Cable, 750 MCM 3 Conductor Type MV-105, 15kV, 133%, Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003eThree conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication \u0026amp; Benefits:\u003c\/strong\u003e\u003cbr\u003ePrysmian’s patented AIRGUARD™ cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations or if installed with cables rated 1000V or greater) with 5X the impact performance and 2X-3X the sidewall bearing pressure limit (@ 3000 lbs per rad-ft) This enables longer pulls than with Continuously Corrugated and Welded type cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMetalic Shield:\u003c\/strong\u003e\u003cbr\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a minimum overlap of 15%. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification -1C w\/Red, 1C w\/Blue, and 1C w\/Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003cbr\u003eBare Stranded copper conductor, one in each interstice, per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003cbr\u003ePhase identified shielded conductors cabled with fillers and grounding conductors (as specified), forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003cbr\u003eHigh strength and high crush resistant Airbag Layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003cbr\u003eA layer of Drylam which consists of aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003eSunlight resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards: \u003c\/strong\u003e \u003cbr\u003eICEA S-93-639\/NEMA WC74 Type MV 105 UL 1072 For CT USE, Direct Buried, Sunlight Resistant, IEEE 383 Flame Test IEEE 1202 Flame Test ICEA T-29-520 at 210,000 BTU\/hr MSHA Type MP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 750\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 220 mils\u003cbr\u003e\u003cb\u003eNumber of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3 \u003cbr\u003e\u003cb\u003eSize of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e4 AWG\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.917 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.41 nches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.47 inches\u003cbr\u003e\u003cb\u003eOverall Jacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3.81 inches\u003cbr\u003e\u003cb\u003eCable Weight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e12.953 lbs per ft\u003cbr\u003e\u003cb\u003eMinumum Bend Radius:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e26 inches\u003cbr\u003e\u003cb\u003eAmpacity:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e105C in Duct =\u003cb\u003e \u003c\/b\u003e 585 amps -  In air =\u003cb\u003e \u003c\/b\u003e 745 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793707262146,"sku":"PGCW4809","price":149.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/15426_d93e65d5-2f36-483e-a6cc-f9d68fbc06ca.webp?v=1771606140"},{"product_id":"prysmian-airguard-cable-500-mcm-3-conductor-type-mv-105-15kv-133-medium-voltage-cable","title":"Prysmian Airguard Cable, 500 MCM 3 Conductor Type MV-105, 15kV, 133%, Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003eThree conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication \u0026amp; Benefits:\u003c\/strong\u003e\u003cbr\u003ePrysmian’s patented AIRGUARD™ cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations or if installed with cables rated 1000V or greater) with 5X the impact performance and 2X-3X the sidewall bearing pressure limit (@ 3000 lbs per rad-ft) This enables longer pulls than with Continuously Corrugated and Welded type cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMetalic Shield:\u003c\/strong\u003e\u003cbr\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a minimum overlap of 15%. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification -1C w\/Red, 1C w\/Blue, and 1C w\/Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003cbr\u003eBare Stranded copper conductor, one in each interstice, per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003cbr\u003ePhase identified shielded conductors cabled with fillers and grounding conductors (as specified), forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003cbr\u003eHigh strength and high crush resistant Airbag Layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003cbr\u003eA layer of Drylam which consists of aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003eSunlight resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards: \u003c\/strong\u003e \u003cbr\u003eICEA S-93-639\/NEMA WC74 Type MV 105 UL 1072 For CT USE, Direct Buried, Sunlight Resistant, IEEE 383 Flame Test IEEE 1202 Flame Test ICEA T-29-520 at 210,000 BTU\/hr MSHA Type MP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 500\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 220 mils\u003cbr\u003e\u003cb\u003eNumber of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3 \u003cbr\u003e\u003cb\u003eSize of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e5 AWG\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.742 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.23 inches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.28 inches\u003cbr\u003e\u003cb\u003eOverall Jacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3.42 inches\u003cbr\u003e\u003cb\u003eCable Weight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e9.568 lbs per ft\u003cbr\u003e\u003cb\u003eMinumum Bend Radius:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e24 inches\u003cbr\u003e\u003cb\u003eAmpacity:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e105C in Duct =\u003cb\u003e \u003c\/b\u003e 485 amps -  In air =\u003cb\u003e \u003c\/b\u003e 600 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793707294914,"sku":"PGCW4808","price":26.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/15426_73b54676-21f2-4093-860f-c44e930432e1.webp?v=1771606142"},{"product_id":"prysmian-airguard-cable-350-mcm-3-conductor-type-mv-105-15kv-133-medium-voltage-cable","title":"Prysmian Airguard Cable, 350 MCM 3 Conductor Type MV-105, 15kV, 133%, Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003eThree conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication \u0026amp; Benefits:\u003c\/strong\u003e\u003cbr\u003ePrysmian’s patented AIRGUARD™ cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations or if installed with cables rated 1000V or greater) with 5X the impact performance and 2X-3X the sidewall bearing pressure limit (@ 3000 lbs per rad-ft) This enables longer pulls than with Continuously Corrugated and Welded type cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMetalic Shield:\u003c\/strong\u003e\u003cbr\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a minimum overlap of 15%. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification -1C w\/Red, 1C w\/Blue, and 1C w\/Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003cbr\u003eBare Stranded copper conductor, one in each interstice, per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003cbr\u003ePhase identified shielded conductors cabled with fillers and grounding conductors (as specified), forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003cbr\u003eHigh strength and high crush resistant Airbag Layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003cbr\u003eA layer of Drylam which consists of aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003eSunlight resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards: \u003c\/strong\u003e \u003cbr\u003eICEA S-93-639\/NEMA WC74 Type MV 105 UL 1072 For CT USE, Direct Buried, Sunlight Resistant, IEEE 383 Flame Test IEEE 1202 Flame Test ICEA T-29-520 at 210,000 BTU\/hr MSHA Type MP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 350\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 220 mils\u003cbr\u003e\u003cb\u003eNumber of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3 \u003cbr\u003e\u003cb\u003eSize of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e6 AWG\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.622 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.11 nches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.16 inches\u003cbr\u003e\u003cb\u003eOverall Jacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3.16 inches\u003cbr\u003e\u003cb\u003eCable Weight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e7.547 lbs per ft\u003cbr\u003e\u003cb\u003eMinumum Bend Radius:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e22 inches\u003cbr\u003e\u003cb\u003eAmpacity:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e105C in Duct =\u003cb\u003e \u003c\/b\u003e 400 amps -  In air =\u003cb\u003e \u003c\/b\u003e 490 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793707393218,"sku":"PGCW4807","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/15426_539486e4-0331-463a-9073-08f80e897489.webp?v=1771606143"},{"product_id":"prysmian-airguard-cable-250-mcm-3-conductor-type-mv-105-15kv-133-medium-voltage-cable","title":"Prysmian Airguard Cable, 250 MCM 3 Conductor Type MV-105, 15kV, 133%, Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003eThree conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication \u0026amp; Benefits:\u003c\/strong\u003e\u003cbr\u003ePrysmian’s patented AIRGUARD™ cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations or if installed with cables rated 1000V or greater) with 5X the impact performance and 2X-3X the sidewall bearing pressure limit (@ 3000 lbs per rad-ft) This enables longer pulls than with Continuously Corrugated and Welded type cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMetalic Shield:\u003c\/strong\u003e\u003cbr\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a minimum overlap of 15%. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification -1C w\/Red, 1C w\/Blue, and 1C w\/Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003cbr\u003eBare Stranded copper conductor, one in each interstice, per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003cbr\u003ePhase identified shielded conductors cabled with fillers and grounding conductors (as specified), forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003cbr\u003eHigh strength and high crush resistant Airbag Layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003cbr\u003eA layer of Drylam which consists of aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003eSunlight resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards: \u003c\/strong\u003e \u003cbr\u003eICEA S-93-639\/NEMA WC74 Type MV 105 UL 1072 For CT USE, Direct Buried, Sunlight Resistant, IEEE 383 Flame Test IEEE 1202 Flame Test ICEA T-29-520 at 210,000 BTU\/hr MSHA Type MP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 250\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 220 mils\u003cbr\u003e\u003cb\u003eNumber of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3 \u003cbr\u003e\u003cb\u003eSize of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e6 AWG\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.522 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.01 nches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.06 inches\u003cbr\u003e\u003cb\u003eOverall Jacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e2.84 inches\u003cbr\u003e\u003cb\u003eCable Weight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e5.932 lbs per ft\u003cbr\u003e\u003cb\u003eMinumum Bend Radius:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e20 inches\u003cbr\u003e\u003cb\u003eAmpacity:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e105C in Duct =\u003cb\u003e \u003c\/b\u003e 335 amps -  In air =\u003cb\u003e \u003c\/b\u003e 400 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793707753666,"sku":"PGCW4806","price":55.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/15426_5d39af60-ed1e-4fe5-b50d-bf8f6ddfd3f7.webp?v=1771606144"},{"product_id":"prysmian-airguard-cable-4-0-awg-3-conductor-type-mv-105-15kv-133-medium-voltage-cable","title":"Prysmian Airguard Cable, 4\/0 AWG 3 Conductor Type MV-105, 15kV, 133%, Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003eThree conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication \u0026amp; Benefits:\u003c\/strong\u003e\u003cbr\u003ePrysmian’s patented AIRGUARD™ cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations or if installed with cables rated 1000V or greater) with 5X the impact performance and 2X-3X the sidewall bearing pressure limit (@ 3000 lbs per rad-ft) This enables longer pulls than with Continuously Corrugated and Welded type cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMetalic Shield:\u003c\/strong\u003e\u003cbr\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a minimum overlap of 15%. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification -1C w\/Red, 1C w\/Blue, and 1C w\/Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003cbr\u003eBare Stranded copper conductor, one in each interstice, per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003cbr\u003ePhase identified shielded conductors cabled with fillers and grounding conductors (as specified), forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003cbr\u003eHigh strength and high crush resistant Airbag Layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003cbr\u003eA layer of Drylam which consists of aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003eSunlight resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards: \u003c\/strong\u003e \u003cbr\u003eICEA S-93-639\/NEMA WC74 Type MV 105 UL 1072 For CT USE, Direct Buried, Sunlight Resistant, IEEE 383 Flame Test IEEE 1202 Flame Test ICEA T-29-520 at 210,000 BTU\/hr MSHA Type MP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 4\/0\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 220 mils\u003cbr\u003e\u003cb\u003eNumber of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3 \u003cbr\u003e\u003cb\u003eSize of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e7 AWG\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.479 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.960 inches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.02 inches\u003cbr\u003e\u003cb\u003eOverall Jacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e2.74 inches\u003cbr\u003e\u003cb\u003eCable Weight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e5.313 lbs per ft\u003cbr\u003e\u003cb\u003eMinumum Bend Radius:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e19 inches\u003cbr\u003e\u003cb\u003eAmpacity:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e105C in Duct =\u003cb\u003e \u003c\/b\u003e 305 amps -  In air =\u003cb\u003e \u003c\/b\u003e 360 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793707851970,"sku":"PGCW4805","price":61.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/15426_f8bbf380-8b9f-497a-bb09-d72f7629cf8e.webp?v=1771606145"},{"product_id":"prysmian-airguard-cable-2-0-awg-3-conductor-type-mv-105-15kv-133-medium-voltage-cable","title":"Prysmian Airguard Cable, 2\/0 AWG 3 Conductor Type MV-105, 15kV, 133%, Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003eThree conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication \u0026amp; Benefits:\u003c\/strong\u003e\u003cbr\u003ePrysmian’s patented AIRGUARD™ cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations or if installed with cables rated 1000V or greater) with 5X the impact performance and 2X-3X the sidewall bearing pressure limit (@ 3000 lbs per rad-ft) This enables longer pulls than with Continuously Corrugated and Welded type cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMetalic Shield:\u003c\/strong\u003e\u003cbr\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a minimum overlap of 15%. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification -1C w\/Red, 1C w\/Blue, and 1C w\/Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003cbr\u003eBare Stranded copper conductor, one in each interstice, per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003cbr\u003ePhase identified shielded conductors cabled with fillers and grounding conductors (as specified), forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003cbr\u003eHigh strength and high crush resistant Airbag Layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003cbr\u003eA layer of Drylam which consists of aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003eSunlight resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards: \u003c\/strong\u003e \u003cbr\u003eICEA S-93-639\/NEMA WC74 Type MV 105 UL 1072 For CT USE, Direct Buried, Sunlight Resistant, IEEE 383 Flame Test IEEE 1202 Flame Test ICEA T-29-520 at 210,000 BTU\/hr MSHA Type MP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 2\/0\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 220 mils\u003cbr\u003e\u003cb\u003eNumber of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3 \u003cbr\u003e\u003cb\u003eSize of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e8 AWG\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.376 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.850 inches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.91 inches\u003cbr\u003e\u003cb\u003eOverall Jacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e2.51 inches\u003cbr\u003e\u003cb\u003eCable Weight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e4.127 lbs per ft\u003cbr\u003e\u003cb\u003eMinumum Bend Radius:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e17 inches\u003cbr\u003e\u003cb\u003eAmpacity:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e105C in Duct =\u003cb\u003e \u003c\/b\u003e 235 amps -  In air =\u003cb\u003e \u003c\/b\u003e 275 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793707884738,"sku":"PGCW4804","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/15426_50f70a8b-c9e7-49cb-bb90-6c4036115dee.webp?v=1771606146"},{"product_id":"prysmian-airguard-cable-1-0-awg-3-conductor-type-mv-105-15kv-133-medium-voltage-cable","title":"Prysmian Airguard Cable, 1\/0 AWG 3 Conductor Type MV-105, 15kV, 133%, Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003ePrysmian Airguard Cable, 1\/0 3 Conductor Type MV-105, 15kV, 133%, Medium Voltage Cable\u003cbr\u003e\u003cbr\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 50' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003eThree conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication \u0026amp; Benefits:\u003c\/strong\u003e\u003cbr\u003ePrysmian’s patented AIRGUARD™ cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations or if installed with cables rated 1000V or greater) with 5X the impact performance and 2X-3X the sidewall bearing pressure limit (@ 3000 lbs per rad-ft) This enables longer pulls than with Continuously Corrugated and Welded type cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMetalic Shield:\u003c\/strong\u003e\u003cbr\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a minimum overlap of 15%. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification -1C w\/Red, 1C w\/Blue, and 1C w\/Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003cbr\u003eBare Stranded copper conductor, one in each interstice, per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003cbr\u003ePhase identified shielded conductors cabled with fillers and grounding conductors (as specified), forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003cbr\u003eHigh strength and high crush resistant Airbag Layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003cbr\u003eA layer of Drylam which consists of aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003eSunlight resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards: \u003c\/strong\u003e \u003cbr\u003eICEA S-93-639\/NEMA WC74 Type MV 105 UL 1072 For CT USE, Direct Buried, Sunlight Resistant, IEEE 383 Flame Test IEEE 1202 Flame Test ICEA T-29-520 at 210,000 BTU\/hr MSHA Type MP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 1\/0\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 220 mils\u003cbr\u003e\u003cb\u003eNumber of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3 \u003cbr\u003e\u003cb\u003eSize of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e8 AWG\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.341 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.820 inches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.880 inches\u003cbr\u003e\u003cb\u003eOverall Jacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e2.43 inches\u003cbr\u003e\u003cb\u003eCable Weight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e3.712 lbs per ft\u003cbr\u003e\u003cb\u003eMinumum Bend Radius:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e17 inches\u003cbr\u003e\u003cb\u003eAmpacity:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e105C in Duct =\u003cb\u003e \u003c\/b\u003e 210 amps -  In air =\u003cb\u003e \u003c\/b\u003e 240 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793707917506,"sku":"PGCW4803","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/15426_8838ebe5-10c5-4f39-8f9d-7f6f165ff80a.webp?v=1771606147"},{"product_id":"prysmian-airguard-cable-1-awg-3-conductor-type-mv-105-15kv-133-medium-voltage-cable","title":"Prysmian Airguard Cable, 1 AWG 3 Conductor Type MV-105, 15kV, 133%, Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 5000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003eThree conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication \u0026amp; Benefits:\u003c\/strong\u003e\u003cbr\u003ePrysmian’s patented AIRGUARD™ cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations or if installed with cables rated 1000V or greater) with 5X the impact performance and 2X-3X the sidewall bearing pressure limit (@ 3000 lbs per rad-ft) This enables longer pulls than with Continuously Corrugated and Welded type cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMetalic Shield:\u003c\/strong\u003e\u003cbr\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a minimum overlap of 15%. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification -1C w\/Red, 1C w\/Blue, and 1C w\/Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003cbr\u003eBare Stranded copper conductor, one in each interstice, per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003cbr\u003ePhase identified shielded conductors cabled with fillers and grounding conductors (as specified), forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003cbr\u003eHigh strength and high crush resistant Airbag Layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003cbr\u003eA layer of Drylam which consists of aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003eSunlight resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards: \u003c\/strong\u003e \u003cbr\u003eICEA S-93-639\/NEMA WC74 Type MV 105 UL 1072 For CT USE, Direct Buried, Sunlight Resistant, IEEE 383 Flame Test IEEE 1202 Flame Test ICEA T-29-520 at 210,000 BTU\/hr MSHA Type MP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 2 AWG\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 220 mils\u003cbr\u003e\u003cb\u003eNumber of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3 \u003cbr\u003e\u003cb\u003eSize of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e10 AWG\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.269 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.740 inches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.790 inches\u003cbr\u003e\u003cb\u003eOverall Jacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e2.210 inches\u003cbr\u003e\u003cb\u003eCable Weight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e3.203 lbs per ft\u003cbr\u003e\u003cb\u003eMinumum Bend Radius:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e16 inches\u003cbr\u003e\u003cb\u003eAmpacity:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e105C in Duct =\u003cb\u003e \u003c\/b\u003e 160 amps -  In air =\u003cb\u003e \u003c\/b\u003e 185 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793707950274,"sku":"PGCW4802","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/15426_a05edb87-8994-4ae6-9ded-d93bb4f819af.webp?v=1771606148"},{"product_id":"prysmian-airguard-cable-2-awg-3-conductor-type-mv-105-15kv-133-medium-voltage-cable","title":"Prysmian Airguard Cable, 2 AWG 3 Conductor Type MV-105, 15kV, 133%, Medium Voltage Cable","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 5000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003eThree conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication \u0026amp; Benefits:\u003c\/strong\u003e\u003cbr\u003ePrysmian’s patented AIRGUARD™ cable is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations or if installed with cables rated 1000V or greater) with 5X the impact performance and 2X-3X the sidewall bearing pressure limit (@ 3000 lbs per rad-ft) This enables longer pulls than with Continuously Corrugated and Welded type cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMetalic Shield:\u003c\/strong\u003e\u003cbr\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a minimum overlap of 15%. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification -1C w\/Red, 1C w\/Blue, and 1C w\/Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGrounding Conductors:\u003c\/strong\u003e\u003cbr\u003eBare Stranded copper conductor, one in each interstice, per UL, ICEA, and ASTM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003c\/strong\u003e\u003cbr\u003ePhase identified shielded conductors cabled with fillers and grounding conductors (as specified), forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e\u003cbr\u003eHigh strength and high crush resistant Airbag Layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e\u003cbr\u003eA layer of Drylam which consists of aluminum tape and a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003eSunlight resistant polyvinyl chloride (PVC) jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards: \u003c\/strong\u003e \u003cbr\u003eICEA S-93-639\/NEMA WC74 Type MV 105 UL 1072 For CT USE, Direct Buried, Sunlight Resistant, IEEE 383 Flame Test IEEE 1202 Flame Test ICEA T-29-520 at 210,000 BTU\/hr MSHA Type MP\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 2 AWG\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 220 mils\u003cbr\u003e\u003cb\u003eNumber of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e3 \u003cbr\u003e\u003cb\u003eSize of Ground Wires:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e10 AWG\u003cbr\u003e\u003cb\u003eConductor Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.269 inches\u003cbr\u003e\u003cb\u003eInsulation Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.740 inches\u003cbr\u003e\u003cb\u003eInsulation Shield Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e0.790 inches\u003cbr\u003e\u003cb\u003eOverall Jacket Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e2.210 inches\u003cbr\u003e\u003cb\u003eCable Weight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e3.203 lbs per ft\u003cbr\u003e\u003cb\u003eMinumum Bend Radius:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e16 inches\u003cbr\u003e\u003cb\u003eAmpacity:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e105C in Duct =\u003cb\u003e \u003c\/b\u003e 160 amps -  In air =\u003cb\u003e \u003c\/b\u003e 185 amps\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793708015810,"sku":"PGCW4801","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/15426_a90e1460-63a1-4b2a-ba59-100ac235bbaf.webp?v=1771606149"},{"product_id":"750-3c-mv-105-w-ground-5kv-8kv-epr-pvc-power-cable-w-copper-tape-shield-133-100-insulation-level","title":"750-3C MV-105, w\/ Ground, 5kV\/8kV, EPR\/PVC Power Cable w\/ Copper Tape Shield, 133%\/100% Insulation Level","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 8kV when installed in open air, conduit, duct or buried directly in the earth, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed as Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B stranded, annealed, bare copper per ASTM B-3 and B-8, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semi-conducting thermoset\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eEthylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e \u003cbr\u003eBased on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e5kV 133% and 8kV 100%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eConductors:\u003c\/b\u003e 3 + 1 Ground\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e 750 MCM\u003cbr\u003e\u003cb\u003eGround Size:\u003c\/b\u003e 1\/0 AWG\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 525\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.140 inches\u003cbr\u003e\u003cb\u003eOutside Diameter: \u003c\/b\u003e3.14 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e9.49 lbs per ft\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793708048578,"sku":"7GCW4800","price":28.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/29263.webp?v=1771606151"},{"product_id":"500-3c-mv-105-w-ground-5kv-8kv-epr-pvc-power-cable-w-copper-tape-shield-133-100-insulation-level","title":"500-3C MV-105, w\/ Ground, 5kV\/8kV, EPR\/PVC Power Cable w\/ Copper Tape Shield, 133%\/100% Insulation Level","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 8kV when installed in open air, conduit, duct or buried directly in the earth, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed as Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B stranded, annealed, bare copper per ASTM B-3 and B-8, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semi-conducting thermoset\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eEthylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e \u003cbr\u003eBased on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e5kV 133% and 8kV 100%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eConductors:\u003c\/b\u003e 3 + 1 Ground\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e 500 MCM\u003cbr\u003e\u003cb\u003eGround Size:\u003c\/b\u003e 1 AWG\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 485\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.110 inches\u003cbr\u003e\u003cb\u003eOutside Diameter: \u003c\/b\u003e2.63 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e6.8 lbs per ft\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793708671170,"sku":"5GCW4799","price":29.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/29263_7037b6c6-ca62-4217-b9d6-4822ba64639e.webp?v=1771606152"},{"product_id":"350-3c-mv-105-w-ground-5kv-8kv-epr-pvc-power-cable-w-copper-tape-shield-133-100-insulation-level","title":"350-3C MV-105, w\/ Ground, 5kV\/8kV, EPR\/PVC Power Cable w\/ Copper Tape Shield, 133%\/100% Insulation Level","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 8kV when installed in open air, conduit, duct or buried directly in the earth, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed as Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B stranded, annealed, bare copper per ASTM B-3 and B-8, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semi-conducting thermoset\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eEthylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e \u003cbr\u003eBased on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e5kV 133% and 8kV 100%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eConductors:\u003c\/b\u003e 3 + 1 Ground\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e 350 MCM\u003cbr\u003e\u003cb\u003eGround Size:\u003c\/b\u003e 2 AWG\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 400\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.110 inches\u003cbr\u003e\u003cb\u003eOutside Diameter: \u003c\/b\u003e2.36 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e5.06 lbs per ft\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793708736706,"sku":"3GCW4798","price":22.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/29263_cc4a8db8-b40e-4e7e-a07a-4b0ec96143f6.webp?v=1771606153"},{"product_id":"4-0-3c-mv-105-w-ground-5kv-8kv-epr-pvc-power-cable-w-copper-tape-shield-133-100-insulation-level","title":"4\/0-3C MV-105, w\/ Ground, 5kV\/8kV, EPR\/PVC Power Cable w\/ Copper Tape Shield, 133%\/100% Insulation Level","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 8kV when installed in open air, conduit, duct or buried directly in the earth, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed as Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B stranded, annealed, bare copper per ASTM B-3 and B-8, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semi-conducting thermoset\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eEthylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e \u003cbr\u003eBased on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e5kV 133% and 8kV 100%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eConductors:\u003c\/b\u003e 3 + 1 Ground\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e 4\/0 AWG\u003cbr\u003e\u003cb\u003eGround Size:\u003c\/b\u003e 3 AWG\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 320\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.110 inches\u003cbr\u003e\u003cb\u003eOutside Diameter: \u003c\/b\u003e2.05 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e3.42 lbs per ft\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793708769474,"sku":"4GCW4797","price":47.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/29263_4a9df098-3186-4ea8-a1a1-dae0df108334.webp?v=1771606154"},{"product_id":"2-0-3c-mv-105-w-ground-5kv-8kv-epr-pvc-power-cable-w-copper-tape-shield-133-100-insulation-level","title":"2\/0-3C MV-105, w\/ Ground, 5kV\/8kV, EPR\/PVC Power Cable w\/ Copper Tape Shield, 133%\/100% Insulation Level","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 8kV when installed in open air, conduit, duct or buried directly in the earth, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed as Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B stranded, annealed, bare copper per ASTM B-3 and B-8, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semi-conducting thermoset\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eEthylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e \u003cbr\u003eBased on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e5kV 133% and 8kV 100%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eConductors:\u003c\/b\u003e 3 + 1 Ground\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e 2\/0 AWG\u003cbr\u003e\u003cb\u003eGround Size:\u003c\/b\u003e 4 AWG\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 235\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.080 inches\u003cbr\u003e\u003cb\u003eOutside Diameter: \u003c\/b\u003e1.82 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e2.45 lbs per ft\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793708802242,"sku":"2GCW4796","price":9.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/29263_0b9f2dd9-e218-4618-b2b7-da06fd689354.webp?v=1771606155"},{"product_id":"1-0-3c-mv-105-w-ground-5kv-8kv-epr-pvc-power-cable-w-copper-tape-shield-133-100-insulation-level","title":"1\/0-3C MV-105, w\/ Ground, 5kV\/8kV, EPR\/PVC Power Cable w\/ Copper Tape Shield, 133%\/100% Insulation Level","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 8kV when installed in open air, conduit, duct or buried directly in the earth, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed as Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B stranded, annealed, bare copper per ASTM B-3 and B-8, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semi-conducting thermoset\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eEthylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e \u003cbr\u003eBased on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e5kV 133% and 8kV 100%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eConductors:\u003c\/b\u003e 3 + 1 Ground\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e 1\/0 AWG\u003cbr\u003e\u003cb\u003eGround Size:\u003c\/b\u003e 4 AWG\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 210\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.080 inches\u003cbr\u003e\u003cb\u003eOutside Diameter: \u003c\/b\u003e1.66 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e2.03 lbs per ft\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793708835010,"sku":"1GCW4795","price":7.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/29263_d1d7a9fe-b73d-4053-b28a-f2b9b1800ef6.webp?v=1771606157"},{"product_id":"2-3c-mv-105-w-ground-5kv-8kv-epr-pvc-power-cable-w-copper-tape-shield-133-100-insulation-level","title":"2-3C MV-105, w\/ Ground, 5kV\/8kV, EPR\/PVC Power Cable w\/ Copper Tape Shield, 133%\/100% Insulation Level","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 8kV when installed in open air, conduit, duct or buried directly in the earth, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed as Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B stranded, annealed, bare copper per ASTM B-3 and B-8, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semi-conducting thermoset\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eEthylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e \u003cbr\u003eBased on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e5kV 133% and 8kV 100%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eConductors:\u003c\/b\u003e 3 + 1 Ground\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e 2 AWG\u003cbr\u003e\u003cb\u003eGround Size:\u003c\/b\u003e 6 AWG\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 160\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.080 inches\u003cbr\u003e\u003cb\u003eOutside Diameter: \u003c\/b\u003e1.51 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e1.51 lbs per ft\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793708900546,"sku":"2GCW4794","price":21.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/29263_28e50832-10ae-46a4-ada1-2fa968cee094.webp?v=1771606158"},{"product_id":"4-3c-mv-105-w-ground-5kv-8kv-epr-pvc-power-cable-w-copper-tape-shield-133-100-insulation-level","title":"4-3C MV-105, w\/ Ground, 5kV\/8kV, EPR\/PVC Power Cable w\/ Copper Tape Shield, 133%\/100% Insulation Level","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 8kV when installed in open air, conduit, duct or buried directly in the earth, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed as Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B stranded, annealed, bare copper per ASTM B-3 and B-8, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semi-conducting thermoset\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eEthylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e \u003cbr\u003eBased on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e5kV 133% and 8kV 100%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eConductors:\u003c\/b\u003e 3 + 1 Ground\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e 4 AWG\u003cbr\u003e\u003cb\u003eGround Size:\u003c\/b\u003e 6 AWG\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 125\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.080 inches\u003cbr\u003e\u003cb\u003eOutside Diameter: \u003c\/b\u003e1.39 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e1.16 lbs per ft\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793708933314,"sku":"4GCW4793","price":19.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/29263_f9c1adf4-cd81-48d1-9a52-4bf04c69f343.webp?v=1771606160"},{"product_id":"6-3c-mv-105-w-ground-5kv-8kv-epr-pvc-power-cable-w-copper-tape-shield-133-100-insulation-level","title":"6-3C MV-105, w\/ Ground, 5kV\/8kV, EPR\/PVC Power Cable w\/ Copper Tape Shield, 133%\/100% Insulation Level","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 8kV when installed in open air, conduit, duct or buried directly in the earth, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed as Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B stranded, annealed, bare copper per ASTM B-3 and B-8, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semi-conducting thermoset\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eEthylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e \u003cbr\u003eBased on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e5kV 133% and 8kV 100%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eConductors:\u003c\/b\u003e 3 + 1 Ground\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e 6 AWG\u003cbr\u003e\u003cb\u003eGround Size:\u003c\/b\u003e 6 AWG\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 95\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.080 inches\u003cbr\u003e\u003cb\u003eOutside Diameter: \u003c\/b\u003e1.29 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.94 lbs per ft\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793708966082,"sku":"6GCW4792","price":3.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/29263_3592428d-8d56-4df1-89cc-319ee534f41f.webp?v=1771606160"},{"product_id":"1000-mcm-mv-105-15kv-epr-pvc-power-cable-w-copper-tape-shield","title":"1000 MCM MV-105, 15kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 15 kV when installed in open air, conduit, duct, or direct buried, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B stranded, annealed, bare copper per ASTM B-3, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semiconducting, thermosetting compound\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eEthylene Propylene Rubber (EPR), physical and electrical properties are in accordance with ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e\u003cbr\u003eBased on three single conductor cables in isolated conduit in air per 2008 NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e15 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 1000 MCM\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.220 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.910 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e 4.225 lbs per ft\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 690 amps\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793708998850,"sku":"1GCW4791","price":46.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/6232.webp?v=1771606161"},{"product_id":"750-mcm-mv-105-15kv-epr-pvc-power-cable-w-copper-tape-shield","title":"750 MCM MV-105, 15kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 100' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 15 kV when installed in open air, conduit, duct, or direct buried, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B stranded, annealed, bare copper per ASTM B-3, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semiconducting, thermosetting compound\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eEthylene Propylene Rubber (EPR), physical and electrical properties are in accordance with ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e\u003cbr\u003eBased on three single conductor cables in isolated conduit in air per 2008 NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e15 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 750 MCM\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e 61\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.220 inches\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.110 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.820 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e 3.415 lbs per ft\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 585 amps\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793709064386,"sku":"7GCW4790","price":47.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/6232_f10fbcd7-4945-4d06-872e-0ab2f80493d3.webp?v=1771606163"},{"product_id":"500-mcm-mv-105-15kv-epr-pvc-power-cable-w-copper-tape-shield","title":"500 MCM MV-105, 15kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 15 kV when installed in open air, conduit, duct, or direct buried, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClass B stranded, annealed, bare copper per ASTM B-3, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semiconducting, thermosetting compound\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEthylene Propylene Rubber (EPR), physical and electrical properties are in accordance with ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBased on three single conductor cables in isolated conduit in air per 2008 NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e15 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 500 MCM\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e 37\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.220 inches\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.080 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.570 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e 2.395 lbs per ft\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 480 amps\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793709097154,"sku":"5GCW4789","price":30.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/6232_e06e3799-cd83-4f69-9f2c-ecdb1ae98f17.webp?v=1771606164"},{"product_id":"350-mcm-mv-105-15kv-epr-pvc-power-cable-w-copper-tape-shield","title":"350 MCM MV-105, 15kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 100' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 15 kV when installed in open air, conduit, duct, or direct buried, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClass B stranded, annealed, bare copper per ASTM B-3, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semiconducting, thermosetting compound\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEthylene Propylene Rubber (EPR), physical and electrical properties are in accordance with ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBased on three single conductor cables in isolated conduit in air per 2008 NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e15 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 350 MCM\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e 37\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.220 inches\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.080 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.440 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e 1.840 lbs per ft\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 395 amps\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793709129922,"sku":"3GCW4788","price":31.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/6232_e86813ca-612f-4cf6-9d53-974110024544.webp?v=1771606165"},{"product_id":"250-mcm-mv-105-15kv-epr-pvc-power-cable-w-copper-tape-shield","title":"250 MCM MV-105, 15kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 15 kV when installed in open air, conduit, duct, or direct buried, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClass B stranded, annealed, bare copper per ASTM B-3, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semiconducting, thermosetting compound\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEthylene Propylene Rubber (EPR), physical and electrical properties are in accordance with ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBased on three single conductor cables in isolated conduit in air per 2008 NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e15 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 250 MCM\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e 37\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.220 inches\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.080 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.340 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e 1.465lbs per ft\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 330 amps\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793709162690,"sku":"2GCW4787","price":15.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/6232_5ea22403-7449-497d-859b-051ef9682cf6.webp?v=1771606166"},{"product_id":"4-0-mv-105-15kv-epr-pvc-power-cable-w-copper-tape-shield","title":"4\/0 MV-105, 15kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 100' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 15 kV when installed in open air, conduit, duct, or direct buried, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClass B stranded, annealed, bare copper per ASTM B-3, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semiconducting, thermosetting compound\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEthylene Propylene Rubber (EPR), physical and electrical properties are in accordance with ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBased on three single conductor cables in isolated conduit in air per 2008 NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e15 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 4\/0\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e 19\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.220 inches\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.080 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.290 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e 1.275lbs per ft\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 260 amps\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793709195458,"sku":"4GCW4786","price":13.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/6232_49826c0e-94b0-4e32-b6dd-82a5ac847028.webp?v=1771606168"},{"product_id":"3-0-mv-105-15kv-epr-pvc-power-cable-w-copper-tape-shield","title":"3\/0 MV-105, 15kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 100' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 15 kV when installed in open air, conduit, duct, or direct buried, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClass B stranded, annealed, bare copper per ASTM B-3, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semiconducting, thermosetting compound\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEthylene Propylene Rubber (EPR), physical and electrical properties are in accordance with ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBased on three single conductor cables in isolated conduit in air per 2008 NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e15 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 3\/0\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e 19\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.220 inches\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.080 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.240 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e 1.130lbs per ft\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 260 amps\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793709228226,"sku":"3GCW4785","price":11.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/6232_b86f751b-19c5-48fe-8844-85824fb4889c.webp?v=1771606174"},{"product_id":"2-0-mv-105-15kv-epr-pvc-power-cable-w-copper-tape-shield","title":"2\/0 MV-105, 15kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 100' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 15 kV when installed in open air, conduit, duct, or direct buried, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClass B stranded, annealed, bare copper per ASTM B-3, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semiconducting, thermosetting compound\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEthylene Propylene Rubber (EPR), physical and electrical properties are in accordance with ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBased on three single conductor cables in isolated conduit in air per 2008 NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e15 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 2\/0\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e 19\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.220 inches\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.080 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.160 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.995 lbs per ft\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 225 amps\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793709260994,"sku":"2GCW4784","price":12.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/6232_71d94a59-3546-404a-b64c-c801f18f0d9b.webp?v=1771606176"},{"product_id":"1-0-mv-105-15kv-epr-pvc-power-cable-w-copper-tape-shield","title":"1\/0 MV-105, 15kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 100' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 15 kV when installed in open air, conduit, duct, or direct buried, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClass B stranded, annealed, bare copper per ASTM B-3, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semiconducting, thermosetting compound\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEthylene Propylene Rubber (EPR), physical and electrical properties are in accordance with ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBased on three single conductor cables in isolated conduit in air per 2008 NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e15 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 1\/0\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e 19\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.220 inches\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.080 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.130 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.870 lbs per ft\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e195 amps\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793709359298,"sku":"1GCW4783","price":12.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/6232_91cebe6f-5dfd-4932-85f0-3f72270335ac.webp?v=1771606177"},{"product_id":"2-awg-mv-105-15kv-epr-pvc-power-cable-w-copper-tape-shield","title":"2 AWG MV-105, 15kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 15 kV when installed in open air, conduit, duct, or direct buried, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClass B stranded, annealed, bare copper per ASTM B-3, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semiconducting, thermosetting compound\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEthylene Propylene Rubber (EPR), physical and electrical properties are in accordance with ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBased on three single conductor cables in isolated conduit in air per 2008 NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e15 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e2 AWG\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e 7\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.220 inches\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.080 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e1.040 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.685 lbs per ft\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e150 amps\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793709981890,"sku":"2GCW4782","price":25.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/6232_f16dfbf4-5405-4201-9785-6888ed86e907.webp?v=1771606179"},{"product_id":"350-mcm-mv-105-5kv-8kv-epr-pvc-power-cable-w-copper-tape-shield-500ft-or-1000ft-spool","title":"350 MCM MV-105, 5kV\/8kV, EPR\/PVC Power Cable w\/ Copper Tape Shield, 500ft or 1000ft Spool","description":"\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 8 kV when installed in open air, conduit, duct or buried directly in the earth, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed as Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B stranded, annealed, bare copper per ASTM B-3 and B-8, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semi-conducting thermoset\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eEthylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e \u003cbr\u003eBased on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e5 kV 133% and 8 kV 100%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 350 MCM\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e 37\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.115 inches\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.080 inches\u003cbr\u003e\u003cb\u003eOutside Diameter: \u003c\/b\u003e1.210 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e 1.500 lbs per ft\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 385 amps\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"500ft Spool","offer_id":45793710211266,"sku":"3GCW4780","price":11495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/8032.webp?v=1771606180"},{"product_id":"4-0-mv-105-5kv-8kv-epr-pvc-power-cable-w-copper-tape-shield-500ft-or-1000ft-spool","title":"4\/0 MV-105, 5kV\/8kV, EPR\/PVC Power Cable w\/ Copper Tape Shield, 500ft or 1000ft Spool","description":"\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 8 kV when installed in open air, conduit, duct or buried directly in the earth, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed as Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B stranded, annealed, bare copper per ASTM B-3 and B-8, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semi-conducting thermoset\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eEthylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e \u003cbr\u003eBased on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e5 kV 133% and 8 kV 100%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 2\/0\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e 19\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.115 inches\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.080 inches\u003cbr\u003e\u003cb\u003eOutside Diameter: \u003c\/b\u003e0.960 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.780 lbs per ft\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 205 amps\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"500ft Spool","offer_id":45793710276802,"sku":"4GCW4778","price":6845.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/8032_3412b381-ff43-43ff-93d3-314ae4136e23.webp?v=1771606181"},{"product_id":"2-0-mv-105-5kv-8kv-epr-pvc-power-cable-w-copper-tape-shield-500ft-or-1000ft-spool","title":"2\/0 MV-105, 5kV\/8kV, EPR\/PVC Power Cable w\/ Copper Tape Shield, 500ft or 1000ft Spool","description":"\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 8 kV when installed in open air, conduit, duct or buried directly in the earth, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed as Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B stranded, annealed, bare copper per ASTM B-3 and B-8, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semi-conducting thermoset\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eEthylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e \u003cbr\u003eBased on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e5 kV 133% and 8 kV 100%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 2\/0\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e 19\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.115 inches\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.080 inches\u003cbr\u003e\u003cb\u003eOutside Diameter: \u003c\/b\u003e0.960 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.780 lbs per ft\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 205 amps\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"500ft Spool","offer_id":45793710309570,"sku":"2GCW4776","price":4745.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/8032_83710b7b-058d-4ea5-82f0-38965db7ee79.webp?v=1771606182"},{"product_id":"2-awg-mv-105-5kv-8kv-epr-pvc-power-cable-w-copper-tape-shield-1000ft-spool","title":"2 AWG MV-105, 5kV\/8kV, EPR\/PVC Power Cable w\/ Copper Tape Shield, 1000ft Spool","description":"\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 8 kV when installed in open air, conduit, duct or buried directly in the earth, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed as Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B stranded, annealed, bare copper per ASTM B-3 and B-8, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semi-conducting thermoset\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eEthylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e \u003cbr\u003eBased on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e5 kV 133% and 8 kV 100%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e2 AWG\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e 7\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.115 inches\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.060 inches\u003cbr\u003e\u003cb\u003eOutside Diameter: \u003c\/b\u003e0.780 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.470 lbs per ft\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e130 amps\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"500ft Spool","offer_id":45793710375106,"sku":"2GCW4774","price":4745.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/8032_3dc54347-5094-4d86-af43-e5e7432d4974.webp?v=1771606183"},{"product_id":"750-mcm-mv-105-5kv-8kv-epr-pvc-power-cable-w-copper-tape-shield","title":"750 MCM MV-105, 5kV\/8kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 100' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 8 kV when installed in open air, conduit, duct or buried directly in the earth, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed as Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B stranded, annealed, bare copper per ASTM B-3 and B-8, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semi-conducting thermoset\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eEthylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e \u003cbr\u003eBased on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e5 kV 133% and 8 kV 100%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 750 MCM\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e 61\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.115 inches\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.080 inches\u003cbr\u003e\u003cb\u003eOutside Diameter: \u003c\/b\u003e1.550 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e 3.025 lbs per ft\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 600 amps\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793710407874,"sku":"7GCW4773","price":27.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/6167_2db15561-af46-4dc0-8b4c-7cd4cfa9d476.webp?v=1771606185"},{"product_id":"500-mcm-mv-105-5kv-8kv-epr-pvc-power-cable-w-copper-tape-shield","title":"500 MCM MV-105, 5kV\/8kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp\u003e\u003cstrong\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/strong\u003e\u003cbr\u003eMinimum 100' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eFor use in power circuits up to 8 kV when installed in open air, conduit, duct or buried directly in the earth, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBlack Polyvinylchloride (PVC) Jacket, sunlight resistant\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003eListed as Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1\/0 and larger marked \"for CT use\" and pass UL 1685 70,000 Btu\/hr flame test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003eClass B stranded, annealed, bare copper per ASTM B-3 and B-8, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semi-conducting thermoset\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003eEthylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e\u003cbr\u003eExtruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmpacity: \u003c\/strong\u003e \u003cbr\u003eBased on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature: \u003c\/strong\u003e \u003cbr\u003e105°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003e \u003cbr\u003e5 kV 133% and 8 kV 100%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications*:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"specs\"\u003e\u003cb\u003eSize:\u003c\/b\u003e 500 MCM\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e 37\u003cbr\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.115 inches\u003cbr\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.080 inches\u003cbr\u003e\u003cb\u003eOutside Diameter: \u003c\/b\u003e1.360 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e 2.130 lbs per ft\u003cbr\u003e\u003cb\u003eAmps per Conductor:\u003c\/b\u003e 475 amps\u003c\/p\u003e\n\u003cp\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793710538946,"sku":"5GCW4772","price":23.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/6167_ffa4e201-ce19-4cd7-93f7-0d295ef264f3.webp?v=1771606187"}],"url":"https:\/\/ayepc2-wv.myshopify.com\/collections\/medium-voltage-cable.oembed","provider":"Testing Developer Store","version":"1.0","type":"link"}