{"title":"Aluminum MV-105, 15kV","description":"","products":[{"product_id":"1-awg-stranded-aluminum-conductor-15kv-urd-133-1-3-neutral","title":"1 AWG Stranded Aluminum Conductor 15KV URD, 133%, 1\/3 Neutral","description":"\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable is primary used for underground distribution, in direct burial or installed in conduit. 15KV URD cable is suitable for use in wet or dry locations. URD cable is to be used at 15,000 volts or less and not to exceed 90°C temperature in normal use.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a solid or compressed concentric strand soft drawn 1350 series aluminum conductor per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has an extruded thermoset semiconducting shield, which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has naturally high dielectric strength TR-XLPE insulation. There is also extruded thermoset semiconducting insulation shield. Optional EPR insulation is available upon request.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eMetalic Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a concentric neutral shield consisting of solid bare copper wires helically applied and uniformly spaced over the insulation shield.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a black jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eASTM B-3, B-8, B230, B-231, B-609 AEIC CS-8 ICEA S-94-649 ICEA T-31-610 ICEA T-34-664 For 90°C continuous, 130°C emergency and 250°C short-circuit operation\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 1 AWG\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Thickness:\u003c\/span\u003e 220 mils\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConcentric Neutral:\u003c\/span\u003e 6-#14\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Diameter: \u003c\/span\u003e0.324 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Diameter: \u003c\/span\u003e0.81 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Shield Diameter: \u003c\/span\u003e0.88 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket Diameter: \u003c\/span\u003e1.12 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eCable Weight:\u003c\/span\u003e 0.521 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAmpacity: \u003c\/span\u003e90°C in Duct =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 144 amps - 90°C Direct Burial =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 199 amps\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793713815746,"sku":"1GCW4747","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/12795.png?v=1771606220"},{"product_id":"2-awg-stranded-aluminum-conductor-15kv-urd-full-neutral-133","title":"2 AWG Stranded Aluminum Conductor 15KV URD, Full Neutral 133%","description":"\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable is primary used for underground distribution, in direct burial or installed in conduit. 15KV URD cable is suitable for use in wet or dry locations. URD cable is to be used at 15,000 volts or less and not to exceed 90°C temperature in normal use.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eConductor:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a solid or compressed concentric strand soft drawn 1350 series aluminum conductor per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eConductor Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has an extruded thermoset semiconducting shield, which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has naturally high dielectric strength TR-XLPE insulation. There is also extruded thermoset semiconducting insulation shield. Optional EPR insulation is available upon request.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eMetalic Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a concentric neutral shield consisting of solid bare copper wires helically applied and uniformly spaced over the insulation shield.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a black jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eASTM B-3, B-8, B230, B-231, B-609 AEIC CS-8 ICEA S-94-649 ICEA T-31-610 ICEA T-34-664 For 90°C continuous, 130°C emergency and 250°C short-circuit operation\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"specs\" style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eSize:\u003c\/span\u003e 2 AWG\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eInsulation Thickness:\u003c\/span\u003e 220 mils\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eConcentric Neutral:\u003c\/span\u003e 10-#14\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eConductor Diameter: \u003c\/span\u003e0.284 inches\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eInsulation Diameter: \u003c\/span\u003e0.77 inches\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eInsulation Shield Diameter: \u003c\/span\u003e0.84 inches\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eJacket Diameter: \u003c\/span\u003e1.08 inches\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eCable Weight:\u003c\/span\u003e 0.533 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eAmpacity: \u003c\/span\u003e90°C in Duct =\u003cspan style=\"font-weight: bold;\"\u003e \u003c\/span\u003e 126 amps - 90°C Direct Burial =\u003cspan style=\"font-weight: bold;\"\u003e \u003c\/span\u003e 175 amps\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793713881282,"sku":"2GCW4746","price":7.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/12801.png?v=1771606221"},{"product_id":"2-awg-solid-aluminum-conductor-15kv-urd-133-1-3-neutral","title":"2 AWG Solid Aluminum Conductor 15KV URD, 133%, 1\/3 Neutral","description":"\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable is primary used for underground distribution, in direct burial or installed in conduit. 15KV URD cable is suitable for use in wet or dry locations. URD cable is to be used at 15,000 volts or less and not to exceed 90°C temperature in normal use.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a solid or compressed concentric strand soft drawn 1350 series aluminum conductor per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has an extruded thermoset semiconducting shield, which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has naturally high dielectric strength TR-XLPE insulation. There is also extruded thermoset semiconducting insulation shield. Optional EPR insulation is available upon request.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eMetalic Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a concentric neutral shield consisting of solid bare copper wires helically applied and uniformly spaced over the insulation shield.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a black jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eASTM B-3, B-8, B230, B-231, B-609 AEIC CS-8 ICEA S-94-649 ICEA T-31-610 ICEA T-34-664 For 90°C continuous, 130°C emergency and 250°C short-circuit operation\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 2 AWG\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Thickness:\u003c\/span\u003e 220 mils\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConcentric Neutral:\u003c\/span\u003e 6-#14\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Diameter: \u003c\/span\u003e0.258 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Diameter: \u003c\/span\u003e0.74 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Shield Diameter: \u003c\/span\u003e0.81 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket Diameter: \u003c\/span\u003e1.05 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eCable Weight:\u003c\/span\u003e 0.466 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAmpacity: \u003c\/span\u003e90°C in Duct =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 126 amps - 90°C Direct Burial =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 175 amps\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793713946818,"sku":"2GCW4745","price":5.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/alum_15kv.png?v=1771606222"},{"product_id":"2-0-stranded-aluminum-conductor-15kv-urd-133-1-3-neutral","title":"2\/0 Stranded Aluminum Conductor 15KV URD, 133%, 1\/3 Neutral","description":"\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable is primary used for underground distribution, in direct burial or installed in conduit. 15KV URD cable is suitable for use in wet or dry locations. URD cable is to be used at 15,000 volts or less and not to exceed 90°C temperature in normal use.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a solid or compressed concentric strand soft drawn 1350 series aluminum conductor per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has an extruded thermoset semiconducting shield, which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has naturally high dielectric strength TR-XLPE insulation. There is also extruded thermoset semiconducting insulation shield. Optional EPR insulation is available upon request.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eMetalic Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a concentric neutral shield consisting of solid bare copper wires helically applied and uniformly spaced over the insulation shield.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a black jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eASTM B-3, B-8, B230, B-231, B-609 AEIC CS-8 ICEA S-94-649 ICEA T-31-610 ICEA T-34-664 For 90°C continuous, 130°C emergency and 250°C short-circuit operation\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 2\/0\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Thickness:\u003c\/span\u003e 220 mils\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConcentric Neutral:\u003c\/span\u003e 7-# 14\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Diameter: \u003c\/span\u003e0.408 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Diameter: \u003c\/span\u003e0.89 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Shield Diameter: \u003c\/span\u003e0.96 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket Diameter: \u003c\/span\u003e1.20 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eCable Weight:\u003c\/span\u003e 0.624 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAmpacity: \u003c\/span\u003e90°C in Duct =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 186 amps - 90°C Direct Burial =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 255 amps\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793713979586,"sku":"2GCW4744","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/12799.png?v=1771606223"},{"product_id":"2-awg-aluminum-mv-105-15kv-epr-pvc-power-cable-w-copper-tape-shield","title":"2 AWG Aluminum MV-105, 15kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003cbr\u003eMinimum 100' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eFor use in aerial, direct burial, cable tray, conduit, and underground duct installations as permitted by the National Electric Code. The cable is capable of operating continuously with a conductor temperature not to exceed 105⁰C for normal operation, 140⁰C for emergency overload conditions, and 250⁰C for short circuit conditions. It is rated at 15,000V with 133% insulation level (ungrounded system). Maximum sidewall pressure is 1000 lbs. This cable does not require the use of pulling lubricant.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eSunlight resistant PVC per ICEA S-97-682, with average thickness in accordance to Table 7-3 of ICEA.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test • UL 1072 – Medium Voltage Power Cables • ICEA S-93-639 (NEMA WC74) – S=46kV Shielded Power Cable fo use in Transmission and Distribution of Electrical Energy\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductors:\u003c\/span\u003e\u003cbr\u003e8000 series aluminum compact conductor in accordance with ASTM specs B800and B801 and ICEA part 2, Section 2.1 and 2.5.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eEthylene propylene rubber (EPR) with a nominal thickness of 0.220\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Shield:\u003c\/span\u003e\u003cbr\u003eExtruded layer of semi-conducting thermosetting material which shall be identified as being semiconducting. Over this layer will be applied a helically wrapped 5-mil copper tape with 25% overlap.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eFlame Tests: \u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eVoltage: \u003c\/span\u003e \u003cbr\u003e15 kV\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 2 AWG\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eMin Jacket Thickness:\u003c\/span\u003e 0.07 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eOutside Diameter: \u003c\/span\u003e0.982 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eWeight:\u003c\/span\u003e 0.488 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAmpacity: \u003c\/span\u003eDuct =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 130 amps - Conduit in air =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 130 amps\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793714012354,"sku":"2GCW4743","price":6.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/10680.png?v=1771606225"},{"product_id":"1-awg-aluminum-mv-105-15kv-epr-pvc-power-cable-w-copper-tape-shield","title":"1 AWG Aluminum MV-105, 15kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003cbr\u003eMinimum 100' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eFor use in aerial, direct burial, cable tray, conduit, and underground duct installations as permitted by the National Electric Code. The cable is capable of operating continuously with a conductor temperature not to exceed 105⁰C for normal operation, 140⁰C for emergency overload conditions, and 250⁰C for short circuit conditions. It is rated at 15,000V with 133% insulation level (ungrounded system). Maximum sidewall pressure is 1000 lbs. This cable does not require the use of pulling lubricant.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eSunlight resistant PVC per ICEA S-97-682, with average thickness in accordance to Table 7-3 of ICEA.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test • UL 1072 – Medium Voltage Power Cables • ICEA S-93-639 (NEMA WC74) – S=46kV Shielded Power Cable fo use in Transmission and Distribution of Electrical Energy\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductors:\u003c\/span\u003e\u003cbr\u003e8000 series aluminum compact conductor in accordance with ASTM specs B800and B801 and ICEA part 2, Section 2.1 and 2.5.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eEthylene propylene rubber (EPR) with a nominal thickness of 0.220\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Shield:\u003c\/span\u003e\u003cbr\u003eExtruded layer of semi-conducting thermosetting material which shall be identified as being semiconducting. Over this layer will be applied a helically wrapped 5-mil copper tape with 25% overlap.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eFlame Tests: \u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eVoltage: \u003c\/span\u003e \u003cbr\u003e15 kV\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 1 AWG\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eMin Jacket Thickness:\u003c\/span\u003e 0.07 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eOutside Diameter: \u003c\/span\u003e1.012 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eWeight:\u003c\/span\u003e 0.523 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAmpacity: \u003c\/span\u003eDuct =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 145 amps - Conduit in air =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 150 amps\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793714045122,"sku":"1GCW4742","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/10682.png?v=1771606227"},{"product_id":"1-0-aluminum-mv-105-15kv-epr-pvc-power-cable-w-copper-tape-shield","title":"1\/0 Aluminum MV-105, 15kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003cbr\u003eMinimum 100' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eFor use in aerial, direct burial, cable tray, conduit, and underground duct installations as permitted by the National Electric Code. The cable is capable of operating continuously with a conductor temperature not to exceed 105⁰C for normal operation, 140⁰C for emergency overload conditions, and 250⁰C for short circuit conditions. It is rated at 15,000V with 133% insulation level (ungrounded system). Maximum sidewall pressure is 1000 lbs. This cable does not require the use of pulling lubricant.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eSunlight resistant PVC per ICEA S-97-682, with average thickness in accordance to Table 7-3 of ICEA.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test • UL 1072 – Medium Voltage Power Cables • ICEA S-93-639 (NEMA WC74) – S=46kV Shielded Power Cable fo use in Transmission and Distribution of Electrical Energy\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductors:\u003c\/span\u003e\u003cbr\u003e8000 series aluminum compact conductor in accordance with ASTM specs B800and B801 and ICEA part 2, Section 2.1 and 2.5.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eEthylene propylene rubber (EPR) with a nominal thickness of 0.220\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Shield:\u003c\/span\u003e\u003cbr\u003eExtruded layer of semi-conducting thermosetting material which shall be identified as being semiconducting. Over this layer will be applied a helically wrapped 5-mil copper tape with 25% overlap.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eFlame Tests: \u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eVoltage: \u003c\/span\u003e \u003cbr\u003e15 kV\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 1\/0\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eMin Jacket Thickness:\u003c\/span\u003e 0.07 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eOutside Diameter: \u003c\/span\u003e1.049 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eWeight:\u003c\/span\u003e 0.575 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAmpacity: \u003c\/span\u003eDuct =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 165 amps - Conduit in air =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 170 amps\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793714077890,"sku":"1GCW4741","price":17.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/10684.png?v=1771606228"},{"product_id":"1000-mcm-aluminum-mv-105-15kv-epr-pvc-power-cable-w-copper-tape-shield","title":"1000 MCM Aluminum MV-105, 15kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eFor use in aerial, direct burial, cable tray, conduit, and underground duct installations as permitted by the National Electric Code. The cable is capable of operating continuously with a conductor temperature not to exceed 105⁰C for normal operation, 140⁰C for emergency overload conditions, and 250⁰C for short circuit conditions. It is rated at 15,000V with 133% insulation level (ungrounded system). Maximum sidewall pressure is 1000 lbs. This cable does not require the use of pulling lubricant.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eSunlight resistant PVC per ICEA S-97-682, with average thickness in accordance to Table 7-3 of ICEA.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test • UL 1072 – Medium Voltage Power Cables • ICEA S-93-639 (NEMA WC74) – S=46kV Shielded Power Cable fo use in Transmission and Distribution of Electrical Energy\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eConductors:\u003c\/span\u003e\u003cbr\u003e8000 series aluminum compact conductor in accordance with ASTM specs B800and B801 and ICEA part 2, Section 2.1 and 2.5.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eEthylene propylene rubber (EPR) with a nominal thickness of 0.220\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eInsulation Shield:\u003c\/span\u003e\u003cbr\u003eExtruded layer of semi-conducting thermosetting material which shall be identified as being semiconducting. Over this layer will be applied a helically wrapped 5-mil copper tape with 25% overlap.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eFlame Tests: \u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eVoltage: \u003c\/span\u003e \u003cbr\u003e15 kV\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"specs\" style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eSize:\u003c\/span\u003e 1000 MCM\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eOutside Diameter: \u003c\/span\u003e1.84 inches\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eWeight:\u003c\/span\u003e 2.03 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eAmpacity: \u003c\/span\u003eDuct =\u003cspan style=\"font-weight: bold;\"\u003e \u003c\/span\u003e 490 amps\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793714110658,"sku":"1GCW4740","price":47.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/34445.png?v=1771606229"},{"product_id":"1000-mcm-stranded-aluminum-conductor-15kv-urd-133-1-3-neutral","title":"1000 MCM Stranded Aluminum Conductor 15KV URD, 133%, 1\/3 Neutral","description":"\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable is primary used for underground distribution, in direct burial or installed in conduit. 15KV URD cable is suitable for use in wet or dry locations. URD cable is to be used at 15,000 volts or less and not to exceed 90°C temperature in normal use.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a solid or compressed concentric strand soft drawn 1350 series aluminum conductor per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has an extruded thermoset semiconducting shield, which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has naturally high dielectric strength TR-XLPE insulation. There is also extruded thermoset semiconducting insulation shield. Optional EPR insulation is available upon request.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eMetalic Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a concentric neutral shield consisting of solid bare copper wires helically applied and uniformly spaced over the insulation shield.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a black jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eASTM B-3, B-8, B230, B-231, B-609 AEIC CS-8 ICEA S-94-649 ICEA T-31-610 ICEA T-34-664 For 90°C continuous, 130°C emergency and 250°C short-circuit operation\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 1000 MCM\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Thickness:\u003c\/span\u003e 220 mils\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConcentric Neutral: \u003c\/span\u003e20-# 10\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Diameter: \u003c\/span\u003e1.124 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Diameter: \u003c\/span\u003e1.63 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Shield Diameter: \u003c\/span\u003e1.74 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket Diameter: \u003c\/span\u003e2.12 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eCable Weight:\u003c\/span\u003e 2.626 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAmpacity: \u003c\/span\u003e90°C in Duct =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 529 amps - 90°C Direct Burial =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 549 amps\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793714143426,"sku":"1GCW4739","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/12791.png?v=1771606230"},{"product_id":"750-mcm-aluminum-mv-105-15kv-epr-pvc-power-cable-w-copper-tape-shield","title":"750 MCM Aluminum MV-105, 15kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eFor use in aerial, direct burial, cable tray, conduit, and underground duct installations as permitted by the National Electric Code. The cable is capable of operating continuously with a conductor temperature not to exceed 105⁰C for normal operation, 140⁰C for emergency overload conditions, and 250⁰C for short circuit conditions. It is rated at 15,000V with 133% insulation level (ungrounded system). Maximum sidewall pressure is 1000 lbs. This cable does not require the use of pulling lubricant.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eSunlight resistant PVC per ICEA S-97-682, with average thickness in accordance to Table 7-3 of ICEA.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test • UL 1072 – Medium Voltage Power Cables • ICEA S-93-639 (NEMA WC74) – S=46kV Shielded Power Cable fo use in Transmission and Distribution of Electrical Energy\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eConductors:\u003c\/span\u003e\u003cbr\u003e8000 series aluminum compact conductor in accordance with ASTM specs B800and B801 and ICEA part 2, Section 2.1 and 2.5.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eEthylene propylene rubber (EPR) with a nominal thickness of 0.220\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eInsulation Shield:\u003c\/span\u003e\u003cbr\u003eExtruded layer of semi-conducting thermosetting material which shall be identified as being semiconducting. Over this layer will be applied a helically wrapped 5-mil copper tape with 25% overlap.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eFlame Tests: \u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eVoltage: \u003c\/span\u003e \u003cbr\u003e15 kV\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"specs\" style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eSize:\u003c\/span\u003e 750 MCM\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eMin Jacket Thickness:\u003c\/span\u003e 0.07 inches\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eOutside Diameter: \u003c\/span\u003e1.639 inches\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eWeight:\u003c\/span\u003e 1.583 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eAmpacity: \u003c\/span\u003eDuct =\u003cspan style=\"font-weight: bold;\"\u003e \u003c\/span\u003e 490 amps - Conduit in air =\u003cspan style=\"font-weight: bold;\"\u003e \u003c\/span\u003e 540 amps\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793714208962,"sku":"7GCW4738","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/10698.png?v=1771606232"},{"product_id":"750-mcm-stranded-aluminum-conductor-15kv-urd-133-1-3-neutral","title":"750 MCM Stranded Aluminum Conductor 15KV URD, 133%, 1\/3 Neutral","description":"\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable is primary used for underground distribution, in direct burial or installed in conduit. 15KV URD cable is suitable for use in wet or dry locations. URD cable is to be used at 15,000 volts or less and not to exceed 90°C temperature in normal use.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a solid or compressed concentric strand soft drawn 1350 series aluminum conductor per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has an extruded thermoset semiconducting shield, which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has naturally high dielectric strength TR-XLPE insulation. There is also extruded thermoset semiconducting insulation shield. Optional EPR insulation is available upon request.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eMetalic Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a concentric neutral shield consisting of solid bare copper wires helically applied and uniformly spaced over the insulation shield.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a black jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eASTM B-3, B-8, B230, B-231, B-609 AEIC CS-8 ICEA S-94-649 ICEA T-31-610 ICEA T-34-664 For 90°C continuous, 130°C emergency and 250°C short-circuit operation\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 750 MCM\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Thickness:\u003c\/span\u003e 220 mils\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConcentric Neutral: \u003c\/span\u003e24-# 12\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Diameter: \u003c\/span\u003e0.974 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Diameter: \u003c\/span\u003e1.48 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Shield Diameter: \u003c\/span\u003e1.56 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket Diameter: \u003c\/span\u003e1.90 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eCable Weight:\u003c\/span\u003e 2.043 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAmpacity: \u003c\/span\u003e90°C in Duct =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 468 amps - 90°C Direct Burial =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 507 amps\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793714241730,"sku":"7GCW4737","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/12789.png?v=1771606233"},{"product_id":"500-mcm-aluminum-mv-105-15kv-epr-pvc-power-cable-w-copper-tape-shield","title":"500 MCM Aluminum MV-105, 15kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003cbr\u003eMinimum 100' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eFor use in aerial, direct burial, cable tray, conduit, and underground duct installations as permitted by the National Electric Code. The cable is capable of operating continuously with a conductor temperature not to exceed 105⁰C for normal operation, 140⁰C for emergency overload conditions, and 250⁰C for short circuit conditions. It is rated at 15,000V with 133% insulation level (ungrounded system). Maximum sidewall pressure is 1000 lbs. This cable does not require the use of pulling lubricant.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eSunlight resistant PVC per ICEA S-97-682, with average thickness in accordance to Table 7-3 of ICEA.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test • UL 1072 – Medium Voltage Power Cables • ICEA S-93-639 (NEMA WC74) – S=46kV Shielded Power Cable fo use in Transmission and Distribution of Electrical Energy\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductors:\u003c\/span\u003e\u003cbr\u003e8000 series aluminum compact conductor in accordance with ASTM specs B800and B801 and ICEA part 2, Section 2.1 and 2.5.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eEthylene propylene rubber (EPR) with a nominal thickness of 0.220\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Shield:\u003c\/span\u003e\u003cbr\u003eExtruded layer of semi-conducting thermosetting material which shall be identified as being semiconducting. Over this layer will be applied a helically wrapped 5-mil copper tape with 25% overlap.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eFlame Tests: \u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eVoltage: \u003c\/span\u003e \u003cbr\u003e15 kV\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 500 MCM\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eMin Jacket Thickness:\u003c\/span\u003e 0.07 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eOutside Diameter: \u003c\/span\u003e1.457 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eWeight:\u003c\/span\u003e 1.217 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAmpacity: \u003c\/span\u003eDuct =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 400 amps - Conduit in air =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 430 amps\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793714274498,"sku":"5GCW4736","price":84.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/10696.png?v=1771606235"},{"product_id":"500-mcm-stranded-aluminum-conductor-15kv-urd-133-1-3-neutral","title":"500 MCM Stranded Aluminum Conductor 15KV URD, 133%, 1\/3 Neutral","description":"\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable is primary used for underground distribution, in direct burial or installed in conduit. 15KV URD cable is suitable for use in wet or dry locations. URD cable is to be used at 15,000 volts or less and not to exceed 90°C temperature in normal use.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a solid or compressed concentric strand soft drawn 1350 series aluminum conductor per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has an extruded thermoset semiconducting shield, which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has naturally high dielectric strength TR-XLPE insulation. There is also extruded thermoset semiconducting insulation shield. Optional EPR insulation is available upon request.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eMetalic Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a concentric neutral shield consisting of solid bare copper wires helically applied and uniformly spaced over the insulation shield.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a black jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eASTM B-3, B-8, B230, B-231, B-609 AEIC CS-8 ICEA S-94-649 ICEA T-31-610 ICEA T-34-664 For 90°C continuous, 130°C emergency and 250°C short-circuit operation\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 500 MCM\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Thickness:\u003c\/span\u003e 220 mils\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConcentric Neutral: \u003c\/span\u003e16-# 12\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Diameter: \u003c\/span\u003e0.794 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Diameter: \u003c\/span\u003e1.29 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Shield Diameter: \u003c\/span\u003e1.38 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket Diameter: \u003c\/span\u003e1.71 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eCable Weight:\u003c\/span\u003e 1.534 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAmpacity: \u003c\/span\u003e90°C in Duct =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 385 amps - 90°C Direct Burial =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 451 amps\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793714307266,"sku":"5GCW4735","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/12809.png?v=1771606235"},{"product_id":"350-mcm-aluminum-mv-105-15kv-epr-pvc-power-cable-w-copper-tape-shield","title":"350 MCM Aluminum MV-105, 15kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003cbr\u003eMinimum 100' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eFor use in aerial, direct burial, cable tray, conduit, and underground duct installations as permitted by the National Electric Code. The cable is capable of operating continuously with a conductor temperature not to exceed 105⁰C for normal operation, 140⁰C for emergency overload conditions, and 250⁰C for short circuit conditions. It is rated at 15,000V with 133% insulation level (ungrounded system). Maximum sidewall pressure is 1000 lbs. This cable does not require the use of pulling lubricant.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eSunlight resistant PVC per ICEA S-97-682, with average thickness in accordance to Table 7-3 of ICEA.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test • UL 1072 – Medium Voltage Power Cables • ICEA S-93-639 (NEMA WC74) – S=46kV Shielded Power Cable fo use in Transmission and Distribution of Electrical Energy\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductors:\u003c\/span\u003e\u003cbr\u003e8000 series aluminum compact conductor in accordance with ASTM specs B800and B801 and ICEA part 2, Section 2.1 and 2.5.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eEthylene propylene rubber (EPR) with a nominal thickness of 0.220\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Shield:\u003c\/span\u003e\u003cbr\u003eExtruded layer of semi-conducting thermosetting material which shall be identified as being semiconducting. Over this layer will be applied a helically wrapped 5-mil copper tape with 25% overlap.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eFlame Tests: \u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eVoltage: \u003c\/span\u003e \u003cbr\u003e15 kV\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 350 MCM\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eMin Jacket Thickness:\u003c\/span\u003e 0.07 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eOutside Diameter: \u003c\/span\u003e1.337 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eWeight:\u003c\/span\u003e 0.994 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAmpacity: \u003c\/span\u003eDuct =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 330 amps - Conduit in air =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 350 amps\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793714340034,"sku":"3GCW4734","price":19.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/10694.png?v=1771606237"},{"product_id":"350-mcm-stranded-aluminum-conductor-15kv-urd-133-1-3-neutral","title":"350 MCM Stranded Aluminum Conductor 15KV URD, 133%, 1\/3 Neutral","description":"\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable is primary used for underground distribution, in direct burial or installed in conduit. 15KV URD cable is suitable for use in wet or dry locations. URD cable is to be used at 15,000 volts or less and not to exceed 90°C temperature in normal use.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a solid or compressed concentric strand soft drawn 1350 series aluminum conductor per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has an extruded thermoset semiconducting shield, which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has naturally high dielectric strength TR-XLPE insulation. There is also extruded thermoset semiconducting insulation shield. Optional EPR insulation is available upon request.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eMetalic Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a concentric neutral shield consisting of solid bare copper wires helically applied and uniformly spaced over the insulation shield.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a black jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eASTM B-3, B-8, B230, B-231, B-609 AEIC CS-8 ICEA S-94-649 ICEA T-31-610 ICEA T-34-664 For 90°C continuous, 130°C emergency and 250°C short-circuit operation\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 350 MCM\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Thickness:\u003c\/span\u003e 220 mils\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConcentric Neutral: \u003c\/span\u003e18-# 14\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Diameter: \u003c\/span\u003e0.664 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Diameter: \u003c\/span\u003e1.16 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Shield Diameter: \u003c\/span\u003e1.25 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket Diameter: \u003c\/span\u003e1.48 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eCable Weight:\u003c\/span\u003e 1.130 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAmpacity: \u003c\/span\u003e90°C in Duct =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 319 amps - 90°C Direct Burial =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 398 amps\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793714569410,"sku":"3GCW4733","price":10.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/12803.png?v=1771606238"},{"product_id":"250-mcm-aluminum-mv-105-15kv-epr-pvc-power-cable-w-copper-tape-shield","title":"250 MCM Aluminum MV-105, 15kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003cbr\u003eMinimum 100' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eFor use in aerial, direct burial, cable tray, conduit, and underground duct installations as permitted by the National Electric Code. The cable is capable of operating continuously with a conductor temperature not to exceed 105⁰C for normal operation, 140⁰C for emergency overload conditions, and 250⁰C for short circuit conditions. It is rated at 15,000V with 133% insulation level (ungrounded system). Maximum sidewall pressure is 1000 lbs. This cable does not require the use of pulling lubricant.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eSunlight resistant PVC per ICEA S-97-682, with average thickness in accordance to Table 7-3 of ICEA.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test • UL 1072 – Medium Voltage Power Cables • ICEA S-93-639 (NEMA WC74) – S=46kV Shielded Power Cable fo use in Transmission and Distribution of Electrical Energy\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductors:\u003c\/span\u003e\u003cbr\u003e8000 series aluminum compact conductor in accordance with ASTM specs B800and B801 and ICEA part 2, Section 2.1 and 2.5.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eEthylene propylene rubber (EPR) with a nominal thickness of 0.220\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Shield:\u003c\/span\u003e\u003cbr\u003eExtruded layer of semi-conducting thermosetting material which shall be identified as being semiconducting. Over this layer will be applied a helically wrapped 5-mil copper tape with 25% overlap.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eFlame Tests: \u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eVoltage: \u003c\/span\u003e \u003cbr\u003e15 kV\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 250 MCM\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eMin Jacket Thickness:\u003c\/span\u003e 0.07 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eOutside Diameter: \u003c\/span\u003e1.242 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eWeight:\u003c\/span\u003e 0.837 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAmpacity: \u003c\/span\u003eDuct =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 270 amps - Conduit in air =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 290 amps\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793714602178,"sku":"2GCW4732","price":18.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/10692.png?v=1771606240"},{"product_id":"250-mcm-stranded-aluminum-conductor-15kv-urd-133-1-3-neutral","title":"250 MCM Stranded Aluminum Conductor 15KV URD, 133%, 1\/3 Neutral","description":"\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable is primary used for underground distribution, in direct burial or installed in conduit. 15KV URD cable is suitable for use in wet or dry locations. URD cable is to be used at 15,000 volts or less and not to exceed 90°C temperature in normal use.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a solid or compressed concentric strand soft drawn 1350 series aluminum conductor per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has an extruded thermoset semiconducting shield, which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has naturally high dielectric strength TR-XLPE insulation. There is also extruded thermoset semiconducting insulation shield. Optional EPR insulation is available upon request.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eMetalic Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a concentric neutral shield consisting of solid bare copper wires helically applied and uniformly spaced over the insulation shield.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a black jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eASTM B-3, B-8, B230, B-231, B-609 AEIC CS-8 ICEA S-94-649 ICEA T-31-610 ICEA T-34-664 For 90°C continuous, 130°C emergency and 250°C short-circuit operation\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 250 MCM\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Thickness:\u003c\/span\u003e 220 mils\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConcentric Neutral: \u003c\/span\u003e13-# 14\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Diameter: \u003c\/span\u003e0.561 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Diameter: \u003c\/span\u003e1.06 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Shield Diameter: \u003c\/span\u003e1.14 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket Diameter: \u003c\/span\u003e1.38 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eCable Weight:\u003c\/span\u003e 0.917 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAmpacity: \u003c\/span\u003e90°C in Duct =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 265 amps - 90°C Direct Burial =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 345 amps\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793714667714,"sku":"2GCW4731","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/12797.png?v=1771606240"},{"product_id":"4-0-awg-aluminum-mv-105-15kv-epr-pvc-power-cable-w-copper-tape-shield","title":"4\/0 AWG Aluminum MV-105, 15kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003cbr\u003eMinimum 25' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eFor use in aerial, direct burial, cable tray, conduit, and underground duct installations as permitted by the National Electric Code. The cable is capable of operating continuously with a conductor temperature not to exceed 105⁰C for normal operation, 140⁰C for emergency overload conditions, and 250⁰C for short circuit conditions. It is rated at 15,000V with 133% insulation level (ungrounded system). Maximum sidewall pressure is 1000 lbs. This cable does not require the use of pulling lubricant.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eSunlight resistant PVC per ICEA S-97-682, with average thickness in accordance to Table 7-3 of ICEA.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test • UL 1072 – Medium Voltage Power Cables • ICEA S-93-639 (NEMA WC74) – S=46kV Shielded Power Cable fo use in Transmission and Distribution of Electrical Energy\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eConductors:\u003c\/span\u003e\u003cbr\u003e8000 series aluminum compact conductor in accordance with ASTM specs B800and B801 and ICEA part 2, Section 2.1 and 2.5.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eEthylene propylene rubber (EPR) with a nominal thickness of 0.220\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eInsulation Shield:\u003c\/span\u003e\u003cbr\u003eExtruded layer of semi-conducting thermosetting material which shall be identified as being semiconducting. Over this layer will be applied a helically wrapped 5-mil copper tape with 25% overlap.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eFlame Tests: \u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eVoltage: \u003c\/span\u003e \u003cbr\u003e15 kV\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"specs\" style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e\u003cspan style=\"font-weight: bold;\"\u003eSize:\u003c\/span\u003e 4\/0\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eMin Jacket Thickness:\u003c\/span\u003e 0.07 inches\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eOutside Diameter: \u003c\/span\u003e1.184 inches\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eWeight:\u003c\/span\u003e 0.758 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: bold;\"\u003eAmpacity: \u003c\/span\u003eDuct =\u003cspan style=\"font-weight: bold;\"\u003e \u003c\/span\u003e 245 amps - Conduit in air =\u003cspan style=\"font-weight: bold;\"\u003e \u003c\/span\u003e 260 amps\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, 'Helvetica Neue', Helvetica, Arial, sans-serif;\"\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793714700482,"sku":"4GCW4730","price":10.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/10690.png?v=1771606243"},{"product_id":"4-0-stranded-aluminum-conductor-15kv-urd-133-full-neutral","title":"4\/0 Stranded Aluminum Conductor 15KV URD, 133%, Full Neutral","description":"\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable is primary used for underground distribution, in direct burial or installed in conduit. 15KV URD cable is suitable for use in wet or dry locations. URD cable is to be used at 15,000 volts or less and not to exceed 90°C temperature in normal use.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor:\u003c\/span\u003e\u003cbr\u003e Solid or compressed concentric stranded 1350 series aluminum conductor per ASTM. The stranded conductors are water-blocked with conductor filling compound.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Shield:\u003c\/span\u003e\u003cbr\u003eExtruded thermoset semiconducting shield, which is free stripping from the conductor and bonded to the insulation\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eNaturally high dielectric strength TR-XLPE insulation. Covered by extruded thermoset semiconducting insulation shield. Optional EPR insulation is available upon request.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eMetalic Shield:\u003c\/span\u003e\u003cbr\u003eConcentric neutral consisting of solid bare copper wires helically applied and uniformly spaced over the insulation shield.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eBlack jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eASTM B230, B231, B609 • ANSI\/ICEA S-94-649 • AEIC CS-8 • RUS ACCEPTED • For 90°C continuous, 130°C emergency and 250°C shortcircuit operation.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 4\/0\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Thickness:\u003c\/span\u003e 220 mils\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConcentric Neutral: \u003c\/span\u003e13-# 10\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Diameter: \u003c\/span\u003e0.515 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Diameter: \u003c\/span\u003e1.00 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Shield Diameter: \u003c\/span\u003e1.07 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket Diameter: \u003c\/span\u003e1.31 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eCable Weight:\u003c\/span\u003e 1.122 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAmpacity: \u003c\/span\u003e90°C in Duct =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 241 amps - 90°C Direct Burial =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 320 amps\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793714733250,"sku":"4GCW4729","price":14.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/12807_1.png?v=1771606243"},{"product_id":"4-0-stranded-aluminum-conductor-15kv-urd-133-1-3-neutral","title":"4\/0 Stranded Aluminum Conductor 15KV URD, 133%, 1\/3 Neutral","description":"\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable is primary used for underground distribution, in direct burial or installed in conduit. 15KV URD cable is suitable for use in wet or dry locations. URD cable is to be used at 15,000 volts or less and not to exceed 90°C temperature in normal use.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a solid or compressed concentric strand soft drawn 1350 series aluminum conductor per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has an extruded thermoset semiconducting shield, which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has naturally high dielectric strength TR-XLPE insulation. There is also extruded thermoset semiconducting insulation shield. Optional EPR insulation is available upon request.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eMetalic Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a concentric neutral shield consisting of solid bare copper wires helically applied and uniformly spaced over the insulation shield.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a black jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eASTM B-3, B-8, B230, B-231, B-609 AEIC CS-8 ICEA S-94-649 ICEA T-31-610 ICEA T-34-664 For 90°C continuous, 130°C emergency and 250°C short-circuit operation\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 4\/0\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Thickness:\u003c\/span\u003e 220 mils\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConcentric Neutral: \u003c\/span\u003e11-# 14\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Diameter: \u003c\/span\u003e0.515 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Diameter: \u003c\/span\u003e1.00 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Shield Diameter: \u003c\/span\u003e1.07 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket Diameter: \u003c\/span\u003e1.31 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eCable Weight:\u003c\/span\u003e 0.803 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAmpacity: \u003c\/span\u003e90°C in Duct =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 241 amps - 90°C Direct Burial =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 320 amps\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793714798786,"sku":"4GCW4727","price":7.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/12807.png?v=1771606246"},{"product_id":"3-0-aluminum-mv-105-15kv-epr-pvc-power-cable-w-copper-tape-shield","title":"3\/0  Aluminum MV-105, 15kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003cbr\u003eMinimum 100' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eFor use in aerial, direct burial, cable tray, conduit, and underground duct installations as permitted by the National Electric Code. The cable is capable of operating continuously with a conductor temperature not to exceed 105⁰C for normal operation, 140⁰C for emergency overload conditions, and 250⁰C for short circuit conditions. It is rated at 15,000V with 133% insulation level (ungrounded system). Maximum sidewall pressure is 1000 lbs. This cable does not require the use of pulling lubricant.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eSunlight resistant PVC per ICEA S-97-682, with average thickness in accordance to Table 7-3 of ICEA.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test • UL 1072 – Medium Voltage Power Cables • ICEA S-93-639 (NEMA WC74) – S=46kV Shielded Power Cable fo use in Transmission and Distribution of Electrical Energy\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductors:\u003c\/span\u003e\u003cbr\u003e8000 series aluminum compact conductor in accordance with ASTM specs B800and B801 and ICEA part 2, Section 2.1 and 2.5.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eEthylene propylene rubber (EPR) with a nominal thickness of 0.220\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Shield:\u003c\/span\u003e\u003cbr\u003eExtruded layer of semi-conducting thermosetting material which shall be identified as being semiconducting. Over this layer will be applied a helically wrapped 5-mil copper tape with 25% overlap.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eFlame Tests: \u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eVoltage: \u003c\/span\u003e \u003cbr\u003e15 kV\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 3\/0\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eMin Jacket Thickness:\u003c\/span\u003e 0.07 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eOutside Diameter: \u003c\/span\u003e1.134 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eWeight:\u003c\/span\u003e 0.690 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAmpacity: \u003c\/span\u003eDuct =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 215 amps - Conduit in air =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 225 amps\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793715060930,"sku":"3GCW4726","price":3.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/10688.png?v=1771606248"},{"product_id":"okonite-161-23-6072-1-0-aluminum-35kv-underground-primary-distribution-cable-epr-full-neutral-100-345ml","title":"Okonite 161-23-6072, 1\/0 Aluminum 35kv Underground Primary Distribution Cable, EPR, Full Neutral 100%,  345ML","description":"\u003cdiv class=\"page\" title=\"Page 1\" style='color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif; font-size: 15px;'\u003e\u003cdiv class=\"layoutArea\"\u003e\u003cdiv class=\"column\"\u003e\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px;\"\u003e\u003cspan style=\"font-weight: 700;\"\u003e35kV Underground Primary Distribution Cable-Jacketed Red Identification Stripes\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAluminum Conductor\/105°C Rating\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003e100% and 133% Insulation Levels\u003c\/span\u003e\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003cbr\u003e\u003c\/span\u003eOkoguard URO-J cables provide maximum circuit longevity in underground residential distribution systems. They can be buried di- rectly or installed in underground ducts or conduits.\u003c\/p\u003e\u003cdiv class=\"page\" title=\"Page 1\" style='color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif; font-size: 15px;'\u003e\u003cdiv class=\"layoutArea\"\u003e\u003cdiv class=\"column\"\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px;\"\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications:\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eCentral Conductor:\u003c\/span\u003e Aluminum per ASTM B-609, Class B stranded per B-231.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px;\"\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Screen:\u003c\/span\u003e Extruded semiconduct- ing ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px;\"\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e Extruded Okoguard meets or ex- ceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px;\"\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Screen:\u003c\/span\u003e Extruded semiconduct- ing ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px;\"\u003e\u003cspan style=\"font-weight: 700;\"\u003eConcentric Conductor:\u003c\/span\u003e Bare copper wires.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px;\"\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e Black Okolene with red extruded stripes meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5 for polyethylene jackets.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003cbr\u003e\u003c\/span\u003eOkoguard is Okonite's registered trade name for its exclusive ethylene-propylene rubber (EPR) based, thermosetting compound, whose optimum balance of electrical and physical properties is unequaled in other solid dielectrics. Okoguard insulation, with the distinctive red color and a totally inte- grated EPR system, provides the optimum balance of electrical and physical properties for long, problem free service.\u003c\/p\u003e\u003cdiv class=\"page\" title=\"Page 1\" style='color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif; font-size: 15px;'\u003e\u003cdiv class=\"layoutArea\"\u003e\u003cdiv class=\"column\"\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px;\"\u003eThe triple tandem extrusion of the screens with the insulation provides optimum electri- cal characteristics.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px;\"\u003eAn insulation screen of ethylene-propylene rubber is extruded over the insulation. The bare copper concentric wires are uniformly spaced around the insulation screen. The overall polyethylene jacket provides protec- tion against mechanical damage and corrosion.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 1.05rem; line-height: 26px;\"\u003eProduct identification is provided through the use of three red stripes placed 120° apart in the black jacket, with an NESC lightning bolt.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eVoltage: \u003c\/span\u003e \u003cbr\u003e35 kV\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 1\/0\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eOutside Diameter: \u003c\/span\u003e1.044 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eWeight:\u003c\/span\u003e 1.17 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAmpacity: \u003c\/span\u003eDuct =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 165 amps @ 90C\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793715126466,"sku":"OGCW4725","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/10686_1_85f05854-77eb-46cb-8cdc-fc90ca795fd9.png?v=1771606249"},{"product_id":"2-0-aluminum-mv-105-15kv-epr-pvc-power-cable-w-copper-tape-shield","title":"2\/0 Aluminum MV-105, 15kV, EPR\/PVC Power Cable w\/ Copper Tape Shield","description":"\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003cbr\u003eMinimum 100' to maximum 1000'. Please call for longer put ups.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eFor use in aerial, direct burial, cable tray, conduit, and underground duct installations as permitted by the National Electric Code. The cable is capable of operating continuously with a conductor temperature not to exceed 105⁰C for normal operation, 140⁰C for emergency overload conditions, and 250⁰C for short circuit conditions. It is rated at 15,000V with 133% insulation level (ungrounded system). Maximum sidewall pressure is 1000 lbs. This cable does not require the use of pulling lubricant.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eSunlight resistant PVC per ICEA S-97-682, with average thickness in accordance to Table 7-3 of ICEA.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test • UL 1072 – Medium Voltage Power Cables • ICEA S-93-639 (NEMA WC74) – S=46kV Shielded Power Cable fo use in Transmission and Distribution of Electrical Energy\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductors:\u003c\/span\u003e\u003cbr\u003e8000 series aluminum compact conductor in accordance with ASTM specs B800and B801 and ICEA part 2, Section 2.1 and 2.5.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eEthylene propylene rubber (EPR) with a nominal thickness of 0.220\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Shield:\u003c\/span\u003e\u003cbr\u003eExtruded layer of semi-conducting thermosetting material which shall be identified as being semiconducting. Over this layer will be applied a helically wrapped 5-mil copper tape with 25% overlap.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eFlame Tests: \u003c\/span\u003e\u003cbr\u003eUL 1685 – 1\/0 and larger, UL-CT Flame Exposure Test\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eVoltage: \u003c\/span\u003e \u003cbr\u003e15 kV\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 2\/0\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eMin Jacket Thickness:\u003c\/span\u003e 0.07 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eOutside Diameter: \u003c\/span\u003e1.089 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eWeight:\u003c\/span\u003e 0.627 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAmpacity: \u003c\/span\u003eDuct =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 190 amps - Conduit in air =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 200 amps\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793715224770,"sku":"2GCW4724","price":9.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/10686.png?v=1771606250"},{"product_id":"1-0-stranded-aluminum-conductor-35kv-urd-full-neutral-100","title":"1\/0 Stranded Aluminum Conductor 35KV URD, Full Neutral 100%","description":"\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 35KV URD cable is primary used for underground distribution, in direct burial or installed in conduit. 35KV URD cable is suitable for use in wet or dry locations. URD cable is to be used at 35,000 volts or less and not to exceed 90°C temperature in normal use.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor:\u003c\/span\u003e\u003cbr\u003eSolid or compressed concentric stranded 1350 series aluminum conductor per ASTM. The stranded conductors are water-blocked with conductor filling compound\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Shield:\u003c\/span\u003e\u003cbr\u003eExtruded thermoset semiconducting shield, which is free stripping from the conductor and bonded to the insulation\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eNaturally high dielectric strength TR-XLPE insulation. Covered by extruded thermoset semiconducting insulation shield. Optional EPR insulation is available upon request\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eMetalic Shield:\u003c\/span\u003e\u003cbr\u003eConcentric neutral consisting of solid bare copper wires helically applied and uniformly spaced over the insulation shield\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eBlack jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eASTM B230, B231, B609 • ANSI\/ICEA S-94-649 • AEIC CS-8 • RUS ACCEPTED • For 90°C continuous, 130°C emergency and 250°C shortcircuit operation\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 1\/0\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Thickness:\u003c\/span\u003e 345 mils\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConcentric Neutral:\u003c\/span\u003e 16‐# 14\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Diameter: \u003c\/span\u003e0.364 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Diameter: \u003c\/span\u003e1.10 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Shield Diameter: \u003c\/span\u003e1.19 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket Diameter: \u003c\/span\u003e1.43 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eCable Weight:\u003c\/span\u003e 0.909 lbs per ft\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793715257538,"sku":"1GCW4723","price":7.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/34090.png?v=1771606252"},{"product_id":"1-0-stranded-aluminum-conductor-25kv-urd-full-neutral-100","title":"1\/0 Stranded Aluminum Conductor 25KV URD, Full Neutral 100%","description":"\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 25KV URD cable is primary used for underground distribution, in direct burial or installed in conduit. 25KV URD cable is suitable for use in wet or dry locations. URD cable is to be used at 25,000 volts or less and not to exceed 90°C temperature in normal use.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 25KV URD cable has a solid or compressed concentric strand soft drawn 1350 series aluminum conductor per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 25KV URD cable has an extruded thermoset semiconducting shield, which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 25KV URD cable has naturally high dielectric strength TR-XLPE insulation. There is also extruded thermoset semiconducting insulation shield. Optional EPR insulation is available upon request.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eMetalic Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 25KV URD cable has a concentric neutral shield consisting of solid bare copper wires helically applied and uniformly spaced over the insulation shield.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 25KV URD cable has a black jacket of linear lows density polyethylene (LDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eASTM B-3, B-8, B230, B-231, B-609 AEIC CS-8\u003cbr\u003eICEA S-94-649\u003cbr\u003eICEA T-31-610\u003cbr\u003eICEA T-34-664\u003cbr\u003eFor 90°C continuous, 130°C emergency and 250°C short-circuit operation\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 1\/0 \u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Thickness:\u003c\/span\u003e 260 mils\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConcentric Neutral:\u003c\/span\u003e 6‐# 14\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Diameter: \u003c\/span\u003e0.364 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Diameter: \u003c\/span\u003e0.93 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Shield Diameter: \u003c\/span\u003e1.00 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket Diameter: \u003c\/span\u003e1.24 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eCable Weight:\u003c\/span\u003e 0.741 lbs per ft\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793715290306,"sku":"1GCW4722","price":7.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/36236.png?v=1771606253"},{"product_id":"1-0-stranded-aluminum-conductor-15kv-urd-133-full-neutral","title":"1\/0 Stranded Aluminum Conductor 15KV URD, 133%, Full Neutral","description":"\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eCut to length - sold by the foot. Enter the desired footage in the QTY box.\u003c\/span\u003e\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eApplications:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable is primary used for underground distribution, in direct burial or installed in conduit. 15KV URD cable is suitable for use in wet or dry locations. URD cable is to be used at 15,000 volts or less and not to exceed 90°C temperature in normal use.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a solid or compressed concentric strand soft drawn 1350 series aluminum conductor per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has an extruded thermoset semiconducting shield, which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has naturally high dielectric strength TR-XLPE insulation. There is also extruded thermoset semiconducting insulation shield. Optional EPR insulation is available upon request.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eMetalic Shield:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a concentric neutral shield consisting of solid bare copper wires helically applied and uniformly spaced over the insulation shield.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket:\u003c\/span\u003e\u003cbr\u003eAluminum Conductor 15KV URD cable has a black jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eStandards:\u003c\/span\u003e\u003cbr\u003eASTM B-3, B-8, B230, B-231, B-609 AEIC CS-8 ICEA S-94-649 ICEA T-31-610 ICEA T-34-664 For 90°C continuous, 130°C emergency and 250°C short-circuit operation\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSpecifications*:\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"specs\" style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e\u003cspan style=\"font-weight: 700;\"\u003eSize:\u003c\/span\u003e 1\/0\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Thickness:\u003c\/span\u003e 220 mils\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConcentric Neutral:\u003c\/span\u003e 6-#14\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eConductor Diameter: \u003c\/span\u003e0.364 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Diameter: \u003c\/span\u003e0.85 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eInsulation Shield Diameter: \u003c\/span\u003e0.92 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eJacket Diameter: \u003c\/span\u003e1.16 inches\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eCable Weight:\u003c\/span\u003e 0.563 lbs per ft\u003cbr\u003e\u003cspan style=\"font-weight: 700;\"\u003eAmpacity: \u003c\/span\u003e90°C in Duct =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 163 amps - 90°C Direct Burial =\u003cspan style=\"font-weight: 700;\"\u003e \u003c\/span\u003e 225 amps\u003c\/p\u003e\u003cp style='margin-bottom: 1.05rem; line-height: 26px; font-size: 15px; color: rgb(39, 38, 38); font-family: FiraSans, \"Helvetica Neue\", Helvetica, Arial, sans-serif;'\u003e*Data provided on this page is subject to change based on different manufacturers variances.\u003c\/p\u003e","brand":"GLOBAL Cable \u0026 Wire","offers":[{"title":"Default Title","offer_id":45793715323074,"sku":"1GCW4721","price":7.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0686\/5603\/8082\/files\/12793.png?v=1771606254"}],"url":"https:\/\/ayepc2-wv.myshopify.com\/collections\/aluminum-mv-105-15kv.oembed?page=2","provider":"Testing Developer Store","version":"1.0","type":"link"}